7800 Series Keypad Installation Guide
13
PRELIMINAR
Y
ChOOSe aCtiOn
OFF Site any On
Choose the Degraded Mode Action required.
Select OFF (Relay Always Off) — The relay does not
turn on when any Wiegand string is received. Off
does not affect any REX operation.
Select SITE (Accept Site Code) — Door access is
granted when the Wiegand site code string received
matches any site code programmed at SITE CODE
ENTRY. For details refer back to the REQUIRE SITE
CODE option.
Select ANY (Any Wiegand Read) — Door access is
granted when any Wiegand string is received.
Select ON (Relay Always On) — The relay is always
on.
ChOOSe aCtiOn
LaSt
Select LAST (Keep Last State) — The relay remains
in the same state and does not change when
communication is lost.
After choosing the action, DEGRADED MODE and the
newly defined action display, programming is complete.
newly defined action display, programming is complete.
Accessing Keypad Diagnostics
If necessary, refer to Access the Keypad Options Menu earlier in this document.
If necessary, refer to Access the Keypad Options Menu earlier in this document.
Kpd Kpd
Opt diag
StOp
Keypad Diagnostics (KPD DIAG)
The Keypad Diagnostic option allows you to check the display
segments, keyboard backlighting and test individual keys.
Press the Select key under KPD DIAG. The keypad lights all
display segments and illuminates the keyboard in Red. In
approximately one second the display backlighting changes
to Green. The keypad alternates between these two states
for approximately two minutes. Press CMD at any time to
begin testing individual keys.
preSS Key tO
teSt
Test Individual Keys
The display changes to PRESS KEY TO TEST. This option tests
each key on the keyboard and the shortcut icons to ensure
proper operation. Touch and hold each key for about two
seconds. The key number being held appears in the display.
Verify the correct number is displaying before testing the
next key.
z1 Open z2 Open
z3 Open z4 Open
z3 Open z4 Open
Zone Test
(7870, 7873 only)
This option allows the keypads to display the current
electrical status of the four protection zones. The status is
shown as OPEN, SHRT, or OKAY.
Note: The Zone Test displays on other keypads, but is not
operational.