Digital Monitoring Products Inc PC0131 Manual De Usuario

Descargar
Página de 22
7800 Series Keypad Installation Guide
PRELIMINAR
Y
Zone 2 Door Contact with Soft-Shunt™ 
If the door being released by the 7873 keypad is protected, you can provide a 
programmed shunt time by connecting its contact to Zone 2 (White/Red pair) on 
the keypad and enabling the Soft-Shunt feature.  See ZONE 2 SHUNT later in this 
document.  Door contacts may be N/C or N/O.  
Note: The Door Strike time is programmable when the keypad is used on an XR100/
XR500 Series panel. 
Zone 3 Request to Exit
You can also connect a N/O PIR (or other motion sensing device) or a mechanical 
switch to Zone 3 (White/Orange pair) on the 7873 keypad to provide request to exit 
capability.  See ZONE 3 EXIT later in this document.  When Zone 3 shorts, the keypad 
relay activates for 5 seconds.  During this time, the user can open the protected door 
to start the programmed Soft-Shunt entry/exit timer.  If the door is not opened within 
5 seconds, the relay restores to its locked state.
Note: A Zone 3 Request to Exit is inhibited for 3 seconds after the keypad reads a card 
and a door strike occurs.  This is to allow area entry and pass under a REX PIR. 
Keypad Backlighting
The touchscreen illuminates at full brightness any time the display is touched.  When 
the speaker is sounding, the backlight illuminates at one-half (1/2) brightness.  During 
an alarm condition, the keyboard and logo turn Red.  When all alarm conditions are 
cleared from the display, the keyboard, logo, and the user-selected brightness is 
restored.  
AC Power/Armed LED Operation
The LED indicates the Power and Armed status of the panel.  Depending on the 
operation, the LED displays in Red or Blue as listed in the table.
Color and Activity Operation
Blue Steady
Panel Disarmed, AC Power OK, Battery OK
Blue Blinking
Panel Disarmed, AC Power OK, Battery Fault
No Light
Panel Disarmed, AC Power Fault, Battery OK
Red Steady
Panel Armed, AC Power OK, Battery OK
Red/Blue Alternate
Panel Armed, AC Power OK, Battery Fault
Red Blinking
Panel Armed, AC Power Fault, Battery OK