Digital Monitoring Products Inc PC0159 Manual De Usuario

Descargar
Página de 36
Digital Monitoring Products 
CellComSL
 
Series Communicator Install/Programming Guide
20
12
Fiji, Marshall Island, Wellington, Auckland, Kwajalein, Kamchatka
13
New Cadelonia
14
Guam, Sydney
15
Tokyo, Seoul
16
Hong Kong, Singapore
17
Bangkok, Hanoi
18
Dhaka, Almaty
19
Islamabad, Karachi
20
Abu Dhabi, Kazan
21
Moscow, Bagdad
22
Eastern Europe
23
Rome, Paris, Berlin
12.10 
Weather Zip Code
This option allows local U.S.A. weather updates to display on the keypad. Enter the zip
code of the user at this prompt. When no number is entered weather conditions are not
displayed. Default is 0 (zero).
Output Options
13.1 
Output Options
This section allows you to program communicator output options. Switched Ground
(open collector) outputs are available using terminals O1 and O2 as the ground and your
burglary control panel for power. Select from outputs 1 or 2.
13.2 
Cutoff Outputs
This option allows you to define the operation of the two on-board outputs. For each
programming option, enter the number of the output you wish to activate or 0 (zero) for
no output. Either or both of the available outputs can be programmed here to turn off
after the time specified in Output Cutoff Time. To disable this option, press any Select
key to clear the display of output numbers and then press COMMAND.
13.2.1 
Output Cutoff Time
If a Cutoff Output is assigned, you can enter a Cutoff Time for the output to remain
on up to 15 minutes. If the output is turned off manually, the cut off time is reset. The 
Cutoff Time can be 1 - 15 minutes. Enter 0 (zero) to provide continuous output.
Note: The output is cutoff within 60 seconds of the programmed cutoff time.
The Cutoff Timer is shared by all outputs. If a second output trips, the timer is not 
reset. Both outputs turn off when the original time expires.
13.3 
Communication Failure Output
This Output/Favorite turns on when the communicator fails to communicate with the 
receiver after three successive dial attempts. Enter 0 (zero) to disable this output. To
turn off the Communication Failure Output, disarm the communicator.
Note: Favorites are only available on the CellComSLCZ Communicator.
13.4 
Armed Output
This Output/Favorite turns on any time an area of the system is armed. The output turns
off when the system completely disarms. Enter 0 (zero) to disable this output.
13.5 
Heat Saver Temperature (CellComSLCZ only)
Enter the desired temperature setting for all Z-Wave thermostats when the system
is armed ALL or AWAY. When the system is disarmed the thermostats return to their
previous settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
13.6 
Cool Saver Temperature (CellComSLCZ only)
Enter the desired temperature setting for all Z-Wave thermostats when the system
is armed ALL or AWAY. When the system is disarmed the thermostats return to their
previous settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
 
ENTER WEATHER 
ZIP CODE:   
OUTPUT OPTIONS
CO OUTS: - - -
CUTOFF TIME:  0
COM FAIL OUT: 0
ARMED OUT:   
0
HEAT SAVER
TEMPERATURE: 0
COOL SAVER
TEMPERATURE: 0
SYSTEM OPTIONS
OUTPUT OPTIONS