iComSL
 
Series Universal Communicator Installation and Programming Guide 
Digital Monitoring Products
17
Output Options
12.1 
Output Options
This section allows you to program communicator output options. Switched Ground
(open collector) outputs are available using terminals O1 and O2 as the ground and your
burglary control panel for power. Select from outputs 1 or 2.
12.2 
Cutoff Outputs
This option allows you to define the operation of the two on-board outputs. For each
programming option, enter the number of the output you wish to activate or 0 (zero) for
no output. Either or both of the available outputs can be programmed here to turn off
after the time specified in Output Cutoff Time. To disable this option, press any Select
key to clear the display of output numbers and then press COMMAND.
12.2.1 
Output Cutoff Time
If a Cutoff Output is assigned, you can enter a Cutoff Time for the output to remain
on up to 15 minutes. If the output is turned off manually, the cut off time is reset. The 
Cutoff Time can be 1 - 15 minutes. Enter 0 (zero) to provide continuous output.
Note: The output is cutoff within 60 seconds of the programmed cutoff time.
The Cutoff Timer is shared by all outputs. If a second output trips, the timer is not 
reset. Both outputs turn off when the original time expires.
12.3 
Communication Failure Output
This Output/Favorite turns on when the communicator fails to communicate with the 
receiver. Enter 0 (zero) to disable this output. To turn off the Communication Failure
Output, disarm the communicator.
Note: Favorites are only available on the iComSLCZ Communicator.
12.4 
Armed Output
This Output/Favorite turns on any time an area of the system is armed. The output turns
off when the system completely disarms. Enter 0 (zero) to disable this output.
12.5 
Remote Arming Output
When the system is armed or disarmed remotely from the Virtual Keypad App, Virtual
Keypad Browser, MyAccess™, RemoteLink™ or from a schedule, this Output turns on
momentary for .75 seconds then turns off. This Output can be used for panels that
require a momentary short to an arming zone to arm and a momentary short to disarm.
12.6 
Heat Saver Temperature (iComSLCZ only)
Enter the desired temperature setting for all Z-Wave thermostats when the system
is armed ALL. When the system is disarmed the thermostats return to their previous
settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
12.7 
Cool Saver Temperature (iComSLCZ only)
Enter the desired temperature setting for all Z-Wave thermostats when the system
is armed ALL. When the system is disarmed the thermostats return to their previous
settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
Area Information
13.1 
Area Information
This section allows you to assign functions to the burglary area of the communicator. 
All non-24-hour zones must be assigned to an active area. See section 14 on Zone
Information.
13.2 
Area Number
Enter the number of the area to program. Select from areas 1 to 6.
13.3 
Area Name
Only those areas given names can have zones assigned to them. All others are marked
*UNUSED*. Refer to the Entering Alpha Characters section.
To add an area name to the system, press any Select key and then enter up to 16
characters for the new name. Press COMMAND to continue.
To mark an active area as unused, delete the old name by pressing any Select key then
press the COMMAND key. The communicator automatically sets the name as *UNUSED*. If
you have already Initialized the communicator, all areas will be marked as *UNUSED*.
OUTPUT OPTIONS
CO OUTS: - - 
CUTOFF TIME:  
0
COM FAIL OUT: 
0
COOL SAVER
TEMPERATURE: 0
AREA INFORMATION
* UNUSED *
ARMED OUT:   
0
RMT ARMG OUT: 
0
HEAT SAVER
TEMPERATURE: 0
AREA NO: -
area InformatIon
output optIons