Laird Controls North America Inc. 79543 Manual De Usuario

Descargar
Página de 19
LRM Radio Module – Host Interface Specification  
 
Test-Specific Parameters  
Document p/n: 9S02-7954-A001 Rev.A 
 
Cattron-Theimeg Inc. 
Proprietary and Confidential 
Page  8-13 
 
8.
 
Test-Specific Parameters 
 
 
Test Mode 
value 
Parameters 
NO_TEST 
None 
TX_CW 
None 
TX_1010 
None 
TX_PRBS 
None 
TX_PACKETS_PRANDOM 
None 
TX_PACKETS_PDEFINED 
testp0: packet data 
CALIB_IFCALIB 
40 
testp0:  
Number of rssi readings averaged. (If testp0 is set to ‘0’, the tests 
automatically presets to ‘1’) 
testp1: 
Progress.  Increments from 0 to 4096 
testp2: 
Current minimum rssi value (dBm, signed integer) 
testp3: 
Current calibration word for this current minimum rssi value 
(uint32).  The four lsb are maintained to zero until the calibration 
complete, where it takes either 0x5 or 0xA depending if the radio 
IC is a ADF7021 or ADF7020 is used. 
RX_RSSI 
81 
None 
RX_STATS 
82 
None 
RX_PACKETS 
83 
None 
RX_BER0 
84 
testp0: 
Calculation window, in msec (default = 200msec).  Result is 
printed after each window time. 
testp1: 
Calculation result from the last window 
RX_BER1 
85 
testp0: 
Calculation window, in msec (default = 200msec) 
testp1: 
Calculation result from the last window