PREVENTATIVE MAINTENANCE
In order to ensure system longevity it is highly recommended that the following preventative maintenance
procedures be done at the appropriate time.
procedures be done at the appropriate time.
Maintenance Schedule
Procedure
Yearly
Quarterly
Monthly
Prior to
Each
Use
Each
Use
Inspect Mounting Hardware on
Tripod, FCII and FCII-AC units
Tripod, FCII and FCII-AC units
■
Inspect All Cables
(connection, chafing)
(connection, chafing)
■
Suggested Spare Parts List
The FCII-AC has two fuses located on the front panel. These are a 4A AC Fuse BMS p/n 514000404 and a
6.3A DC Fuse BMS p/n 514000463.
6.3A DC Fuse BMS p/n 514000463.
There are no other serviceable parts. Any attempts to service any other individual components may void
the warranty.
the warranty.
Fuse Replacement Procedure
Tools Needed
Standard Screwdriver
1. Remove the old fuse by using the screwdriver to unscrew the fuse cap on the front panel of the
control panel (see Figure 18 and Figure 19 )
2. Remove the old fuse & dispose.
3. Insert new fuse into the fuse holder.
4. Replace the fuse cap using a screwdriver to secure it in place.