Broadcast Microwave Services Inc FC-FCII-7 Manual De Usuario

Descargar
Página de 42
 
 
24
PREVENTATIVE MAINTENANCE 
In order to ensure system longevity it is highly recommended that the following preventative maintenance 
procedures be done at the appropriate time.    
Maintenance Schedule 
Procedure 
Yearly 
Quarterly 
Monthly 
Prior to 
Each 
Use 
Inspect Mounting Hardware on 
Tripod, FCII and FCII-AC units 
 
 
 
■ 
Inspect All Cables 
(connection, chafing) 
 
 
 
■ 
 
 
Suggested Spare Parts List 
The FCII-AC has two fuses located on the front panel.  These are a 4A AC Fuse BMS p/n 514000404 and a 
6.3A DC Fuse BMS p/n 514000463. 
There are no other serviceable parts.  Any attempts to service any other individual components may void 
the warranty. 
 
Fuse Replacement Procedure 
 
Tools Needed 
Standard Screwdriver 
 
1.  Remove the old fuse by using the screwdriver to unscrew the fuse cap on the front panel of the 
control panel (see Figure 18 and Figure 19 ) 
2.  Remove the old fuse & dispose. 
3.  Insert new fuse into the fuse holder. 
4.  Replace the fuse cap using a screwdriver to secure it in place.