Rothenbuhler Engineering Company Inc 1673-2 Manual De Usuario

Descargar
Página de 68
1673 OPERATION MANUAL REV A 
2.2.4. 
The Remote 
Unit’s shock tube circuit develops a high voltage spark to initiate 
non-electric shock tube. 
2.2.5. 
The Remote Unit can run on standby for typically 12-16 hours before 
recharging is required. The Remote Unit’s charger is internal and is capable of 
worldwide operation. Typical charge time is 3 hours. The battery system features test 
and discharge functions. 
2.2.6. 
The Remote Unit features an internal history event log which stores 1024 
events in non-volatile memory. The history log can be used to obtain information on the 
operation and performance of the RFD. Each event is logged with the current date and 
time along with GPS coordinates (if available). 
2.3. 
BATTERY CHARGERS 
2.3.1. 
Both Controller and Remote Units use internal battery chargers which are 
powered by +12VDC from an external AC adapter. The AC adapter operates from 100
240VAC, 50-60 Hz, and has changeable pins for worldwide operation.  Typical charge 
time is 3 hours. Charging should be conducted indoors.  Do not attempt to substitute 
another power supply or equipment damage may occur. 
2.3.2. 
For battery charging procedure, refer to Section 3.2. 
2.4. 
ENABLE KEYS 
2.4.1. 
Each system is supplied with a unique group of enable keys.  The enable 
keys contain the encoded information required for operation. 
2.4.2. 
The Controller Unit has a unique enable key, and will only arm and fire with 
this specific key installed.  The Controller Unit will perform status and disarm functions 
without the key installed.  The Controller Unit automatically disarms all Remote Units 
upon key removal.  The Controller key 
is labeled with a ‘C’ to distinguish it from the 
Remote keys. 
2.4.3. 
The Remote Units’ use of the enable key can be configured for one of two 
operation modes. 
2.4.3.1.  In generic (default) mode, the Remote unit assumes its System and Unit 
numbers from the key installed. Any key can work in any Remote unit (as long as that 
Remote is on the correct frequency assignment). Generic mode allows the flexibility to 
move Remote Units within different systems and units within those systems by changing 
the keys. 
2.4.3.2.  In dedicated mode, The Remote Unit is setup to only work with one specific 
key; for example a Remote Unit setup in dedicated to be Remote #3 from System #8 
can only work with a key that matches these values. Dedicated mode can help when a 
very strict key control plan is required.