1673 OPERATION MANUAL REV A 
23 
3.  Insert the tube into the igniter port on the side. Slide the tube into the igniter port until the 
tube comes to a firm stop. 
4.  Pull the tube exiting the guide hole, removing any slack in the loop formed.  This prevents 
the tube from coming loose from the igniter needle.  Do not allow the tube to form a kink.   
2.11.3. 
Tip Care.  The two tips provided with the RFD are rugged, and will each last for up to 
500 shots if properly cared for.  Take care to keep mud and debris from getting on the igniter 
needle.  In some cases, the tip’s life can be extended by washing in soapy water and gently 
rubbing the igniter needle with a non-metallic device such as a cotton swab.  
2.11.4. 
Tip Replacement.  It is recommended the tip be replaced at regular intervals to prevent 
the likelihood of misfires resulting from worn tip electrodes.  You may choose to hold one tip in 
reserve as a replacement or spare at a location apart from your RFD.  Then estimate your tip 
usage, and schedule replacement when the tip’s use reaches your estimated 500 shots.