Cleaning and maintaining the antenna module
14
  
|
  ADN-W AM
– Closed access mode (“
Wireless Menu
” > “
Access Mode
” >
Closed
”)
Only wireless conference units whose serial numbers are listed in
a participant list can be used in the wireless conference. If several
wireless conferences are held simultaneously, the closed access
mode ensures that the wireless conference units connect to the
correct conference system. This access mode increases the pro-
tection against eavesdropping because only selected and
enabled wireless conference units can be used.
Cleaning and maintaining the 
antenna module
Only use a dry and soft cloth to clean the product.
Specifications ADN-W AM
Further information on how to configure the wireless confer-
ence components can be found in the ADN system manual.
RF frequency range
2.4 GHz; 5.1 to 5.9 GHz
RF output power
25 to 100 mW (depending on the selected 
country/region)
Power supply
12 to 15 V 
alternatively via ADN 
PORT
 bus 52.8 V
Power consumption
6 W
Antennas
3 rod antennas with R-SMA connection
Transmission range
typ. 30 m
Mounting thread
5/8" and 3/8" thread insert
Temperature range
operation: +5°C to +45°C
storage: -25°C to +70°C
Relative humidity
operation: 20 to 95% 
storage: 10 to 90% 
Dimensions (W x H x D)
approx. 226 x 181 x 58 mm
Weight
approx. 1,660 g