OMG plc VICP1 Manual De Usuario

Descargar
Página de 45
Origin 
Setup & 
Maintenance 
Guide 
Vicon Motion Systems Ltd.
04-Sep-2018
Page 23 of 45
1. Gear up
a. Enable group clusters:
• On System tab, select clusters in group and select the 
Enabled check box.
b. Check cluster statuses are green and error flags are clear.
c. Participants move to calibration area.
d. Check that all objects are tracking well.
2. Experience
a. Send Start Experience command.
b. Participants move into volume and experience begins.
c. Experience ends.
d. Send Stop Experience command.
3. Gear down
a. Participants move to calibration area.
b. Disable group clusters:
• On System tab, select clusters in group and clear the Enabled 
check box.
It is assumed that there are four areas involved:
• Gear up/gear down area for Group A
• Gear up/gear down area for Group B
• Calibration area for group activation/deactivation and tracking checks
• Tracking volume (where experience takes place)
In the gear-up/gear down areas, the clusters must be able to connect to the 
Beacon, enabling the software to monitor status and battery level. 
Connectivity depends on the physical layout and distance from the Beacon.
The calibration area must be adjacent to the main tracking volume, both for 
seamless tracking and for good radio connectivity.
DRAFT