Checkpoint Systems Inc. EVOLVEF10 Manual De Usuario

Descargar
Página de 71
F10 Installation Manual 
                         Rev. *60          
 
14 of 71
 
 
  Common interfering elements and their minimum distances from F10 Antennas are listed below: 
  Expansion Joints:  The minimum distance from an expansion joint is 0.6 m [2 ft].  
  Vertical Cabling: The minimum distance from vertical cabling is 2.4 m [8 ft]. 
  Metal Wall Studs: The minimum distance from a metal wall stud is 0.9 m [3 ft]. 
  Sliding Doors (Metal): The minimum distance from a metal sliding door is 1.2 m [4 ft]. 
  Tagged Merchandise: The minimum distance from tagged merchandise is 1.8 m [6 ft]. 
  Inward and Outward Swinging Doors (Metal): The minimum distance from either a 
manual- or automatic-swinging metal door frame is 0.6 m [2 ft]. 
Although this last type of door is not shown in the figure, the fact that swinging metal doors can 
swing toward the antenna loop must be taken into account (see below).  
  Note:  The antenna must not be located below the door (or too near the door) when fully opened. Locate the 
F10 antenna components beyond the door – with a minimum clearance gap of 0.6m [24in].  
Other Checkpoint equipment could interfere with the F10 system or vice se versa (refer 
to 
 for recommended separation distances).  
System Performance Considerations 
Nearby wiring and lighting, as well as floor construction, may affect performance. With RF 
interference that is too severe and cannot be alleviated, the site may not be suitable for any 
installations.  
The detection field is not uniform (refer to 
 for diagrams). 
Each of the following alters F10 system performance:  
•  Spacing between the antenna and steel deck in the floor can affect performance, but it 
has been observed that an increase in detection can occur when the F10 system is placed 
on any metal flooring. 
•  Floor structure may cause detection variation for the F10 system. 
•  Antenna configuration will cause an expected (known) change in detection heights and 
a unique coverage pattern. Refer to 
 for detail.  
•  Signal strength - The plots in the appendix have a defined height at TX = 31 (the 
maximum). If TX is less than 31, detection heights will decrease. 
Determining the Electronics Location   
During the site survey, evaluate the store’s layout to learn what options are available for locating 
the electronics enclosure and power supply. The electronics and power supply may be placed close 
together, although this is not required. Both units may be placed under a cashwrap counter, under 
shelving, above a drop ceiling (see special requirements), or in a utility closet. 
The updated power supply can be installed in the plenum (i.e., above a drop ceiling or in HVAC 
areas), but this requires a conversion kit (refer to 
 for complete details). 
If necessary, the electronics enclosure can be located in the plenum – and as long as the power 
supply is located outside of the plenum – no conversion kit is required.  
   Note:
  
Since the “Hood Kit” (CKP P/N: 7367100) must be ordered separately, determine whether or not one 
is needed now. 
 Caution: If using the conversion kit, the power supply must be installed by a licensed electrician.