Checkpoint Systems Inc. EVOLVEREM Manual De Usuario

Descargar
Página de 27
Classic IP Style SSB Installation Manual                           Rev.*60          
 
12 of 27
 
 
Wire Routing 
 
Methods of Wire Routing  
 
  Floor Trench: Typically 1.3cm [.5in.] wide by 3.8cm [1.5in.], but an increase in 
dimensions is recommended for more than two antennas.  
  Wiremold: 1500 or 2600 series wire mold can be utilized. Typically wire mold is not 
used within customer traffic areas, so a typical placement is from the outside of the 
antennas to the doorframe.  
  Conduit: 2.5cm [1in.] diameter conduit can be utilized in new construction situations. It is 
recommended that swept 90 degree angles are used, and that pull-strings are provided by 
the conduit installer.  
  Wall / Mullion: Wires can be contained within mullions, and hollow walls for vertical 
wire runs.  
  Dek-Duct / Panduit: Wires can be contained within surface mount Dek-Duct or Panduit 
for vertical wire runs. 
 
W
ARNING
Any wiring in plenum areas must be plenum rated. Additionally, ensure that the 
wire is installed in accordance with applicable (local/national) electrical codes