Classic Street Installation Manual 
                         Rev. *60         
 
13 of 28
 
Wire Routing 
 
Methods of Wire Routing  
The cabling between PSB and SSB has to be routed either under floor or through floor wiremold. 
“Up & Over” routing method is not permitted for cabling between PSB and SSB. 
 
 
Figure 4 Methods of Wire Routing 
 
 
Floor Trench: Typically 1.3cm [.5in.] wide by 3.8cm [1.5in.], but an increase in 
dimensions is recommended for more than two antennas.  
 
Wiremold: 1500 or 2600 series wire mold can be utilized. Typically wire mold is not 
used within customer traffic areas, so a typical placement is from the outside of the 
antennas to the doorframe.  
 
Conduit: 2.5cm [1in.] diameter conduit can be utilized in new construction situations. It is 
recommended that swept 90 degree angles are used, and that pull-strings are provided by 
the conduit installer.  
 
Wall / Mullion: Wires can be contained within mullions, and hollow walls for vertical 
wire runs.  
 
Dek-Duct / Panduit: Wires can be contained within surface mount Dek-Duct or Panduit 
for vertical wire runs. 
 
W
ARNING
Any wiring in plenum areas must be plenum rated. Additionally, ensure that the 
wire is installed in accordance with applicable (local/national) electrical codes
Correct Wire Routing 
(A) 
Incorrect Wire Routing 
(B) 
OR