The following is a diagram of wiring the Performa reader to a Checkpoint Terminal Controller:
Dip Switch Settings
LED and beeper features are controlled by a dip switch pack located on the back of the reader.  The first
three positions of the dip switch pack is all that is needed to change the output of the LED and beeper.  The
fourth dip switch is reserved for future use.  The following chart shows the dip switch setting and
functionality of the LED and beeper.  The LED is bi-color and can provide Red, Green, and Amber states.
The beeper is a standard piezo or magnetic beeper.
Switches
Note
LED
Beeper
SW 1
SW 2
SW 3
Ready
Denied
Admit
Denied
Admit
ON
ON
ON
GREEN
R/G FLASH
RED 3s
3 SHORT
NONE
ON
ON
OFF
RED
R/G FLASH
GREEN 3s
3 SHORT
NONE
ON
OFF
OFF
RED
R/G FLASH
NO CHANGE
3 SHORT
1 LONG
OFF
ON
ON
RED
R/G FLASH
GREEN 3s
3 SHORT
1 LONG
OFF
OFF
OFF
1
RED
FLICKERS
FLICKERS
CHIRPS
CHIRPS
Notes:
1.  This is a test mode for the reader.  This strictly tests the reader itself and indicates no functionality of
the Terminal Controller.
Note: Please refer to your
hardware for use of the
beeper control and the
sixth wire.  Checkpoint
does not land the beeper
control wire to its own
board.
JM P 8
Reader 1
V oltage
JM P 7
Reader 2
V oltage
Jum per 7 and 8 N um bering
3   (top)
2   (center)
1   (bottom )
Ba
tter
y
LE D
"0"
"1"
5V
G N D
12v
5v
Brown
White
Red
Black
Green