Checkpoint Systems Inc. TR7240 Manual De Usuario

Descargar
Página de 14
Checkpoint Systems, Inc.
  –  Field Service Installation Document  –  CKP P/N 
#######
Page 6 of 9
2.2.2 Two Readers Four Aisles (2R4A)
 
Figure 7: 
2 AP Pedestals configured for widest application “2R4A” - 2 readers driving 4 aisles
This layout requires 2 AP pedestals/kits, and then 2 PNs (either can be removed for a half 
aisle on that side), as well as 1 PP in the center aisle position. 4 Full Aisles are covered. 
(Outside of the total aisle span, there is NO backfield detection; therefore, the far left and 
right Pedestals should be up against a wall or other physical blocking objects.)
1. Use interpedestal coax cable to connect RX7 of first AA to RX5 of first PN.
2.  Use interpedestal coax cable to connect RX8 of first AA to RX6 of first PN.
3.  Use interpedestal coax cable to connect RX3 of first AA to RX5 of PP.
4.  Use interpedestal coax cable to connect RX4 of first AA to RX6 of PP.
5.  Use interpedestal coax cable to connect RX3 of second AA to RX9 of PP.
6.  Use interpedestal coax cable to connect RX4 of second AA to RX10 of PP.
7.  Use interpedestal coax cable to connect RX7 of second AA to RX5 of second PN.
8.  Use interpedestal coax cable to connect RX8 of second AA to RX6 of second PN.
9.  Use interpedestal network cable to connect “Interpedestal OUT” of first PN to “Interpedestal IN” of first AA.
10. Use interpedestal network cable to connect “Interpedestal OUT” of first AA to “Interpedestal IN” of PP.
11. Use interpedestal network cable to connect “Interpedestal OUT” of PP to “Interpedestal IN” of second AA.
12. Use interpedestal network cable to connect “
Interpedestal OUT” 
of second AA to
 “Interpedestal IN” of second PN
.
13. Connect 12 VDC to the WRTZ reader using power supply system.
Advanced I/O
Name
Purpose
For more details
Digital In / Out connector (4-Pin Euro)
General purpose digital relays
see Input/Output
Serial Port via Standard 8-Pin RJ-45
Connect to FS laptop via Serial 
cable
see Serial applications
Outputs for Alarm Lights and Sound
2-Pin LTS/SND standard euro-
block connectors, with +12V DC 
output 
see Complete Wiring