Honeywell International Inc. WLUWIFIM010 Manual De Usuario
CAGE CODE:
97896
SCALE: NONE
SIZE: A
DWG NO.
REV:
SHEET 16
HIF-1472R6(1)
12
WLAN_LINK_STAT
O
13
POWER_GOOD
O
14
DISC_OUT_1
Spare
O
15
DISC_OUT_2
Spare
O
16
DISC_OUT_3
Spare
O
17
JTAG_EXT_EN
I
18
FL_UNPROTECT
I
19
EE_UNPROTECT
I
20
JTAG_AW_EXT
I
21
+28VDC RTN
GND
22
+28VDC
I
23
CHASSIS_GND
GND
24
JTAG_TDO_EXT
O
25
GND
26
JTAG_TCK_EXT
I
27
GND
28
JTAG_TDI_EXT
I
29
GND
30
JTAG_TMS_EXT
I
Table 3-3 gives the name and position and describes where the Ethernets are located on the main connector.
Table 8-4 J1-A Quadrax Insert Positions
Position
Name
Description
1
Eth1 (Primary)
CIS Server Port
2
(Filled with alum. Plug)
3
Eth2 (Secondary)
CWLU Port
Table 3-4 gives the name and position of the Ethernet pins to describe how they will be electrically connected.
Table 8-5 J1-A Insert Quadrax Pinout
Quadrax Pin
Signal
Labels
1
TX+
PRI_10_100_TX_A/SEC_10_100_TX_A
2
RX+
PRI_10_100_RX_A/SEC_10_100_RX_A
3
TX-
PRI_10_100_TX_B/SEC_10_100_TX_B
4
RX-
PRI_10_100_RX_B/SEC_10_100_RX_B
Shell
Shield
Ground
9.
MECHANICAL INSTALLATION
9.1.
General
This section contains information on the necessary information to mount the WLU.
Figure 9-1 shows the WLU mounting hole dimensions, as well as the mechanical outline. The depth or
protrusion of the J1 and J2 connectors are 0.78 inches maximum. The WLU is a bolt-down low profile package
with the footprint defined in ARINC 763.
protrusion of the J1 and J2 connectors are 0.78 inches maximum. The WLU is a bolt-down low profile package
with the footprint defined in ARINC 763.