3.6  Quick Start - General Config 
All LMU-2x30s™ must go through a common step during the configuration and 
provisioning process. Specifically, this is pointing the LMU to the LM Direct™ server, either 
via IP or a URL 
This configuration process is accomplished via a series of AT Commands. 
 
1.  Power up the LMU-2x30™ 
2.  Plug the serial cable into your laptop 
3.  Open a terminal session to the LMU-2x30™ 
4.  Enter the address of the LM Direct™ server.  
AT$APP PARAM 768,0,ddd.ddd.ddd.ddd 
AT$APP PARAM 769,0,ppppp 
 
where ddd.ddd.ddd.ddd is the publicly addressable IPV4 address of the server and 
ppppp is the UDP port number 
 
The LMU-2x30™ will respond with: OK 
5.  Alternatively if a URL has been set up it may be programmed with:  
AT$APP PARAM 2319,0, “myURL.MyCompany.Com” 
Where “myURL.MyCompany.com” is the URL assigned to the server, the LMU-
2x30™ will respond with: OK  
 
Note that if you are not using a URL, this field must be cleared using: 
AT$APP PARAM 2319,0, “” 
6.  Verify your settings by using: 
AT$APP INBOUND?