Application Note 
Version:
 
1.0 
 
Feature
:   
Bluetooth Support  
Page #: 
6 of 11
 
 
3.4  LMU user serial message  configuration parameters setup example.  
•  If user data packets from the remote device are required to be transmitted to the 
backend server at a rate above one per five seconds, the User Message Disposition 
S-Register must be set to unacknowledged Message: 
S-137< VALUE = 5> 
ats137=5 
•  Configure serial message filters: 
at$app param 2178,0,"" 
at$app param 2178,1,"" 
at$app param 2178,2,"" 
at$app param 2178,3,"" 
at$app param 2178,4,"" 
at$app param 2178,5,"" 
at$app param 2178,6,"" 
at$app param 2178,7,"" 
Use the same as above for 2176 app param: 
at$app param 2176,0,"" 
at$app param 2176,1,"" 
at$app param 2176,2,"" 
at$app param 2176,3,"" 
at$app param 2176,4,"" 
at$app param 2176,5,"" 
at$app param 2176,6,"" 
at$app param 2176,7,"" 
 
•  Ensure that these new configurations do not cause any stream conflicts. Send the 
query: 
at$app stream? 
Below is an example of a stream conflict: 
              at$app stream? 
Stream         Port         Rate    Word 
------        ----         ----    ---- 
 0:User0       8:BTPort     9600    8/N/1 
 1:Modem       4:Radio      115200  8/N/1 
 2:User1       -- 
 3:Debug       0:Aux1       115200  8/N/1 PREEMPT 
 4:NMEA Out    -- 
 5:DUN         --