Interface Specification Document
Rev.  -
Cellular Radio Module
 
CRM4250/4200
Company Confidential
Standard Communications Corp.
-5- 
 
November 20, 2000
3.2 Physical
The host interface to the CRM4250/4200 is implemented using a 20 pin (2x10) header
connector. It provides all connections between the CRM4250/4200 and the base band
controller and/or data modem.
PIN  SMBOL           I/O                   DESCRIPTION
1,2  GND
GND
Ground.
SPKR OUT
O
 
High Power Audio (Ear/Speaker)
LINE A
RX demodulated signal (+)
+/-8.0kHz deviation input will produce
1 volt p-p output signal (variable level
with 99h command) for modem use.
SPKR OUT 
High Power Audio (Ringer).
LINE IN
I
TX modulation (+)
1 volt p-p signal,
will produce +/-8.0kHz deviation.
Single-ended input (600 ohm)
LINE B 
Fixed -18dBm modem audio output.
MIC 
Microphone audio input. Can be
directly connected to 600 ohm
impedance microphone or Electric
type microphone.
9,10 VCC                PWR
(CRM4200 ONLY) +5 VDC supply input.
Requires a minimum available current of
750mA. (DO NOT CONNECT IF CRM4250)
11  reserved 
Do not connect.
12  RSSI 
Receive signal strength indication.
Varying DC voltage output based on
received signal strength.
13,14 VCC  
PWR 
(CRM4250 ONLY) +12VDC supply input
Requires a minimum available current of
1.2 amps. (DO NOT CONNECT IF CRM4200)