Honeywell International Inc. KSN770 Manual De Usuario

Descargar
Página de 248
Draft
Page 3-123
6 Dec 2012
34-70-06
SYSTEM INSTALLATION MANUAL
066-01204 / 066-01213
© Honeywell International Inc. Do not copy without express permission of Honeywell.
3.17 Miscellaneous Interface
3.17.1 Applicable Part Numbers
All part numbers and software revisions perform all miscellaneous functions.
3.17.2 Function
3.17.2.1
Cooling
Two fans are used as the primary method of providing internal cooling to the KSN 7xx. Aircraft supply 
of forced air cooling is not required. Two externally mounted cooling fans (part of KSN 7xx equipment 
rack design) provide all required cooling for the KSN 7xx.
3.17.2.2
Configuration Module
The configuration module is used to keep implementation specific setup information on board the 
aircraft. This facilitates configuration of the KSN 7xx in the event service is needed.
3.17.2.3
WOW Input
The WOW input is configurable in the maintenance pages to be active either high or low, and must 
be configured correctly for proper operation.
3.17.2.4
Spare, Reserved only Pins
This is a list of spare pins that are included in the KSN 7xx, but not used in installation, and is for 
reference only.
3.17.3 Requirements and Limitations
3.17.3.1
Cooling
N/A
3.17.3.2
Configuration Module
N/A
3.17.3.3
WOW Input
N/A
3.17.3.4
Spare Pins
N/A
Draft as of 10/15/2012