4.   AT+INSTRUCTION  INTRODUCTION 
4.1. Configuration Mode 
When HF-A11x power up, it will default works as transparent transmission mode, then user can 
switch to configuration mode by serial port command. HF-A11x UART default parameters setting 
as below figure, 
 
 
Figure 39.  HF-A11x Default UART Port Parameters 
In configuration mode, user can setting the module through AT+ instruction set, which cover all 
web page setting function. 
4.1.1.  Switch to Configuration Mode 
Two steps to finish switching from transparent transmission mode to configuration mode. 
 
¾  UART input “+++”, after module receive “+++”, and feedback “a” as confirmation. 
¾  UART input “a”, after module receive “a” and feedback “+ok” to go into AT+ 
instruction set configuration mode. 
 
 
Figure 40.  Switch to Configuration Mode 
Notes: 
1. When user input “+++” (No “Enter” key required), the UART port will display feedback 
information “a”, and not display input information”+++” as above UART display. 
2. Any other input or wrong step to UART port will cause the module still works as original mode 
(transparent transmission).