Both sensors must trigger to cause the detector to signal an 
alarm. The Detector uses quad PIR technology to deliver precise, 
reliable presence detection.  
Programmable options include a variable pulse count and a 
choice of three detection ranges: 10 m / 33 ft., 20 m / 66 ft., 
and 30 m / 98 ft. 
The integral dual-axis tilt sensor allows 180° of pan and 90° of 
tilt. This increases the speed of the outdoor installation and 
provides incredibly accurate aiming of the detection pattern. 
The electronics module is acrylic coated for additional 
component stability. It is encased in a vandal-resistant, high-
impact, UV stabilized plastic housing with an opaque 
polyethylene front cover ensuring that the sensor is impervious 
to and unaffected by weather conditions. 
The combination of precision electronics, digital white light 
filtering, and double shielding eliminates false alarms from the 
sun and other visible light sources. 
The Detector design has a neat and professional appearance that 
gives no visible indication of the orientation of the detector 
head and totally hides the wiring. 
Quick installation 
1.  Mount and connect the detector following the instructions 
given later in this sheet. 
2. 
The detection LED (blue) flashes three times. 
3.  Wait approximately 2 to 3 minutes to allow the detector to 
settle. 
4.  Press the programming button once to activate walk test 
mode. 
The detection LED is now enabled for five minutes. 
Note: 
The front cover must be fitted when walk testing. 
The default settings are: 
‡ 
Range: 30 meters / 98 feet 
‡ 
Pulse count: 1 
Mounting the unit 
During installation, protect the electronics against water, as 
trapped moisture can affect or damage the unit. 
To mount the detector: 
1.  Drill the wall to accept the two fixing screws and 
the tamper cup (if used). See Figures 1 and 3.  
A hole-drilling template is provided.  
Notes 
‡ 
Leave a minimum 10 cm (4 inches) clearance above 
the top of the detector housing to allow the cover and 
the detector to be positioned correctly. 
‡ 
We recommend using the tamper cup on uneven wall 
surfaces. 
‡ 
The recommended optimum mounting height for the 
detector is 3 m. Whilst it is possible to mount the unit 
higher, this will give a reduced detection range and 
will require the detection subject to move further 
through the already reduced detection area before an 
activation is signalled. 
2.  Remove the cover assembly by loosening the locking 
screw. 
Squeeze the sides of the front cover to release the internal 
catches. The cover hinges from the top and lifts out of the 
location slot. See Figure 2. 
3.  Screw the unit to the wall ensuring that the tamper pin is 
correctly located and that the tamper microswitch is 
closed. 
To aid installation, two spare different length tamper 
The tamper foot is a push 
fit and can be removed by carefully pulling it from the pin. 
See Figure 1. 
4.  When the detector is aligned, connected, and 
programmed to suit the installation: 
a.  Fit the cover to the detector base. 
b.  Lightly screw the locking screw using a star screwdriver. 
c.  Put the top of the locking tool into the small notch on 
each side of the cover, and then apply slight pressure 
until the cover locks into the base, as shown in 
Figure 17. 
d.  Tighten the locking screw. 
Fitting the Batteries 
Multibeam alignment and masking 
The multifunction lens fitted to the detector produces 
seven long-range beams and seven medium- to short-range 
curtain PIR beams. The PIR circuitry detects changes in heat 
and movement in the beam pattern; therefore items such as 
trees, shrubs, ponds, boiler flues, and animals should be 
considered when positioning the detector. 
Battery
Only use battery type 3V Lithium CR123 (x 2 provided)  This will 
provide 3 years operation under normal conditions.  
For extended battery life a 3rd battery can be fitted into the rear 
of the TX board, See Fig 5.
Observe correct polarity when fitting. 
Battery safety information
Do not dispose of in a fire
Do not heat
Do not charge
Do not short circuit
Do not disassemble
Only replace with same type and voltage
feet are provided. 
Fit the 2x CR123 batteries provided into the top battery case. 
Observe correct polarity.  See Fig 4. 
P/1‡REV 2.‡ISS 19APR12