UTC Fire & Security Americas Corporation Inc 787E-SIMON Manual De Usuario

Descargar
Página de 44
10
Programming
2.
Set the house code for the installation.
3.
Plug the module into a wall outlet.
4.
Plug the lamp/appliance into the module.
CAUTION!
Do not plug in appliances or lamps with 300-watt or 
larger bulbs into Lamp Modules.
Universal Module
1.
Set the unit code dial to a unit number different from all 
other X-10 modules (between 1 and 8).
2.
Set the house code for the installation.
3.
Set the module switches to momentary and relay only.
4.
Connect the module terminals to the desired device ter-
minals.
5.
Plug the universal module into a wall outlet.
Note 
See “Light and Appliance Controls” to program a Key-
chain Touchpad to activate a Universal Module controlled 
device.
Sensor Installation
Program sensors and devices before you install them. Use the 
following section to program the panel and add the sensors to 
panel memory.
Programming
Entering Program Mode
There are 2 codes you can use to enter program mode.
Utility Access Code 1 (Dealer Code)
Depending upon how Option 54 is set, the default utility access 
code is 654321, 54321, 4321 (factory default), or 321. This 
code can be used for all programming.
Utility Access Code 2 (Installer Code)
Depending upon how Option 54 is set, the default access code 
is 654321, 54321, 4321 (factory default), or 321. This code is 
limited to changing all but the following: Utility Access Code 
1, Options 4, 5, 6, 8, 9, 12, 13, 54, and 69.
1.
Open the panel cover.
2.
Enter Utility Access Code 1 or 2 using the numbered 
keys.
The panel is now in program mode. Follow the programming 
arrows on the panel label. The system prompts you through 
programming steps with beeps and voice messages.
Note 
Do not remove panel power while in program mode. Pro-
gramming changes are saved only when exiting program 
mode (closing the panel cover).
Program the panel in this order:
1.
Set the panel clock.
2.
Add (learn) sensors.
3.
Set House Code and Light & Appliance Controls 
(Entry/Exit activated lights, Sensor activated lights, 
Time activated lights).
4.
Change numbered Options as needed.
Exiting Program Mode
Close the cover to exit program mode when you are finished 
programming.
CAUTION!
Do not power down the panel while in program mode 
or all programming will be lost. The panel stores 
programmed information only when you exit program 
mode (close the cover and leave closed for at least 5 
seconds).
Reset Memory to the Factory Defaults
1.
Open the panel cover and enter Utility Access code 1.
2.
Unplug the transformer and disconnect the battery.
3.
Simultaneously press and hold CancelClock Set, and 
Minutes +.
4.
Restore power to the panel with either the battery or the 
transformer while pressing these three buttons. The 
panel announces “Hello. System XX OK.” Release the 
buttons.
5.
Connect the remaining power source to the panel.
Note 
If Option 8: Phone Lock is on, options 04, 05, 06, 08, 09, 
12, and 13 will not reset to their defaults.
Set the Clock
1.
Press Clock Set from the Start Menu.
2.
Press the Hours + and 
– 
keys and listen to the voice 
prompts. Stop when panel voice announces the correct 
hour.
3.
Press the Minutes + and 
– 
keys and listen to the voice 
prompts. Stop when the panel announces the correct 
minutes.
4.
Press Done. The panel announces the set time.
Adding (Learning) Sensors
These instructions describe how to add sensors, touchpads and 
other system devices into panel memory. The panel recognizes 
a sensor when you press a sensor program button, press and 
release a tamper switch, press a sensor test button, or put a sen-
sor into alarm.
Note 
The hardwire inputs must have sirens or hardwire sen-
sors with 47k Ohm resistors connected between the 
DCOUT and HWIN1 or HWIN2 terminals before learning 
in a sensor. If one of these connections is not made, the 
panel will learn in a hardwire zone.
Note 
If you are installing a sensor on a gun case, jewelry box, 
or similar usage, and the sensor is active in level one, 
you must sub-disarm to avoid putting the panel into alarm 
when the sensor and the magnet are separated.
The following table, “Device Programming,” describes the 
programming button location for each device.