UTC Fire & Security Americas Corporation Inc 787E-SIMON Manual De Usuario

Descargar
Página de 44
13
Programming
Option 01: Panel Piezo Beeps (Default = On)
Determines whether the panel piezo produces beeps based on 
system activity (on) or is silent (off). The following table 
describes all possible beeps.
To turn on Panel Piezo Beeps, press:
Add—Option #—01—DONE.
To turn off Panel Piezo Beeps, press:
Delete—Option #—01—DONE.
Note 
For all UL listed systems, Option 1 must be on (added).
Option 02: Panel Voice (Default = On)
Determines whether the panel announces all status, alarm, and 
program mode messages (on), or only announces messages for 
canceled alarms, open sensors (protesting), when SYSTEM 
STATUS is pressed, or if the panel is in program mode (off).
To turn on Panel Voice, press:
Add—Option #—02—DONE.
To turn off Panel Voice, press:
Delete—Option #—02—DONE.
Option 03: Latchkey (Default = Off)
Determines whether the panel reports a Latchkey alarm if the 
system is not disarmed at a preset time between midnight and 
11:59 
P
.
M
. (on), or if the Latchkey feature is disabled (off).
Note 
The system clock must be set for the Latchkey feature to 
work.
To set Latchkey, press:
Add—Option #—03—Hours—Minutes—DONE.
To turn off Latchkey, press:
Delete—Option #—03—DONE.
Option 04: Primary Phone Number (Default = none)
Lets you program up to a 26-digit central monitoring station 
receiver phone number for monitored systems (on), or delete 
an existing primary phone number (off).
Press Test for each required pause, Add for a *, and Delete for 
a # (each of which uses one of the 26 available places).
To set Primary Phone Number, press:
Add—Option #—04—Up to 26 digits—DONE.
Note 
Pressing DONE is required if you enter fewer than 26 
digits. The phone number is automatically stored without 
pressing DONE if all 26 places are used.
To delete Primary Phone Number, press:
Delete—Option #—04—DONE.
Option 05: Secondary Phone Number
(Default = none)
Lets you program up to a 26-digit central monitoring station 
receiver/numeric pager/voice event notification phone number 
for monitored systems (on), or delete an existing secondary 
phone number (off).
Press Test for each required pause, Add for a *, and Delete for 
a # (each of which uses one of the 26 available places).
Panel Piezo Beeps
Activity
Piezo Beep Response
ARM Doors & 
Windows
Exit Delay—2 beeps sound every 5 
seconds and 2 times per second during 
the last 10 seconds.
Silent Exit—2 beeps sound at the 
beginning of the exit delay and 2 more 
sound just before the exit delay expires.
Entry Delay—2 beeps sound every 5 
seconds and 2 times per second during 
the last 10 seconds.
ARM Motion 
Sensors
Exit Delay—3 beeps sound every 5 
seconds and 3 times per second during 
the last 10 seconds.
Silent Exit—3 beeps sound at the 
beginning of the exit delay and 3 more 
sound just before the exit delay expires.
Entry Delay—3 beeps sound every 5 
seconds and 3 times per second during 
the last 10 seconds.
ARM Doors/
Windows & 
Motion Sensors
Exit Delay—4 beeps sound every 5 
seconds and 4 times per second during 
the last 10 seconds.
Silent Exit—4 beeps sound at the 
beginning of the exit delay and 4 more 
sound just before the exit delay expires.
Entry Delay—4 beeps sound every 5 
seconds and 4 times per second during 
the last 10 seconds.
DISARM
1 beep
CHIME 
DOORS 
2 beeps (when programmed)
CHIME 
SPECIAL 
MOTION
3 beeps (when programmed)
Trouble Beeps
6 beeps every minute. Press SYSTEM 
STATUS to stop beeps for 4 hours.
No Activity
20 beeps every minute for 5 minutes 
(when programmed)