10
Programming
2.
Set the house code for the installation.
3.
Plug the module into a wall outlet.
4.
Plug the lamp/appliance into the module.
CAUTION!
Do not plug in appliances or lamps with 300-watt or
larger bulbs into Lamp Modules.
Do not plug in appliances or lamps with 300-watt or
larger bulbs into Lamp Modules.
Universal Module
1.
Set the unit code dial to a unit number different from all
other X-10 modules (between 1 and 8).
other X-10 modules (between 1 and 8).
2.
Set the house code for the installation.
3.
Set the module switches to momentary and relay only.
4.
Connect the module terminals to the desired device ter-
minals.
minals.
5.
Plug the universal module into a wall outlet.
Note
See “Light and Appliance Controls” to program a Key-
chain Touchpad to activate a Universal Module controlled
device.
chain Touchpad to activate a Universal Module controlled
device.
Sensor Installation
Program sensors and devices before you install them. Use the
following section to program the panel and add the sensors to
panel memory.
following section to program the panel and add the sensors to
panel memory.
Programming
Entering Program Mode
There are 2 codes you can use to enter program mode.
Utility Access Code 1 (Dealer Code)
Depending upon how Option 54 is set, the default utility access
code is 654321, 54321, 4321 (factory default), or 321. This
code can be used for all programming.
code is 654321, 54321, 4321 (factory default), or 321. This
code can be used for all programming.
Utility Access Code 2 (Installer Code)
Depending upon how Option 54 is set, the default access code
is 654321, 54321, 4321 (factory default), or 321. This code is
limited to changing all but the following: Utility Access Code
1, Options 4, 5, 6, 8, 9, 12, 13, 54, and 69.
is 654321, 54321, 4321 (factory default), or 321. This code is
limited to changing all but the following: Utility Access Code
1, Options 4, 5, 6, 8, 9, 12, 13, 54, and 69.
1.
Open the panel cover.
2.
Enter Utility Access Code 1 or 2 using the numbered
keys.
keys.
The panel is now in program mode. Follow the programming
arrows on the panel label. The system prompts you through
programming steps with beeps and voice messages.
arrows on the panel label. The system prompts you through
programming steps with beeps and voice messages.
Note
Do not remove panel power while in program mode. Pro-
gramming changes are saved only when exiting program
mode (closing the panel cover).
gramming changes are saved only when exiting program
mode (closing the panel cover).
Program the panel in this order:
1.
Set the panel clock.
2.
Add (learn) sensors.
3.
Set House Code and Light & Appliance Controls
(Entry/Exit activated lights, Sensor activated lights,
Time activated lights).
(Entry/Exit activated lights, Sensor activated lights,
Time activated lights).
4.
Change numbered Options as needed.
Exiting Program Mode
Close the cover to exit program mode when you are finished
programming.
programming.
CAUTION!
Do not power down the panel while in program mode
or all programming will be lost. The panel stores
programmed information only when you exit program
mode (close the cover and leave closed for at least 5
seconds).
Do not power down the panel while in program mode
or all programming will be lost. The panel stores
programmed information only when you exit program
mode (close the cover and leave closed for at least 5
seconds).
Reset Memory to the Factory Defaults
1.
Open the panel cover and enter Utility Access code 1.
2.
Unplug the transformer and disconnect the battery.
3.
Simultaneously press and hold Cancel, Clock Set, and
Minutes +.
Minutes +.
4.
Restore power to the panel with either the battery or the
transformer while pressing these three buttons. The
panel announces “Hello. System XX OK.” Release the
buttons.
transformer while pressing these three buttons. The
panel announces “Hello. System XX OK.” Release the
buttons.
5.
Connect the remaining power source to the panel.
Note
If Option 8: Phone Lock is on, options 04, 05, 06, 08, 09,
12, and 13 will not reset to their defaults.
12, and 13 will not reset to their defaults.
Set the Clock
1.
Press Clock Set from the Start Menu.
2.
Press the Hours + and
–
keys and listen to the voice
prompts. Stop when panel voice announces the correct
hour.
hour.
3.
Press the Minutes + and
–
keys and listen to the voice
prompts. Stop when the panel announces the correct
minutes.
minutes.
4.
Press Done. The panel announces the set time.
Adding (Learning) Sensors
These instructions describe how to add sensors, touchpads and
other system devices into panel memory. The panel recognizes
a sensor when you press a sensor program button, press and
release a tamper switch, press a sensor test button, or put a sen-
sor into alarm.
other system devices into panel memory. The panel recognizes
a sensor when you press a sensor program button, press and
release a tamper switch, press a sensor test button, or put a sen-
sor into alarm.
Note
The hardwire inputs must have sirens or hardwire sen-
sors with 47k Ohm resistors connected between the
DCOUT and HWIN1 or HWIN2 terminals before learning
in a sensor. If one of these connections is not made, the
panel will learn in a hardwire zone.
sors with 47k Ohm resistors connected between the
DCOUT and HWIN1 or HWIN2 terminals before learning
in a sensor. If one of these connections is not made, the
panel will learn in a hardwire zone.
Note
If you are installing a sensor on a gun case, jewelry box,
or similar usage, and the sensor is active in level one,
you must sub-disarm to avoid putting the panel into alarm
when the sensor and the magnet are separated.
or similar usage, and the sensor is active in level one,
you must sub-disarm to avoid putting the panel into alarm
when the sensor and the magnet are separated.
The following table, “Device Programming,” describes the
programming button location for each device.
programming button location for each device.