B.  Press the field next to Enter Device Name and enter the name of the Z-Wave Device via the keyboard. Press SAVE
C.  For a single partition system, press CONTINUE and proceed to step D. For a multiple partition system, press SELECT 
PARTITIONS FOR THIS DEVICE to select the partitions to which this device is assigned. Press SAVE, then press 
CONTINUE
D.  If the device has been added successfully (and all devices have been added), press CLOSE. Verify all devices are 
present.  
Note: If the add process failed, a red screen will appear. Press RESET to reset the device to its factory defaults; this is 
useful if the device is not responding or if the device has been previously installed to a different controller. Press RETRY to 
attempt to add again. 
To Edit Z-Wave Device(s) 
1.  From the Z-Wave devices screen, press EDIT to edit the name or partition details of a Z-Wave device. 
2.  When finished editing, press SAVE to return to the Z-Wave device menu. 
To Delete Z-Wave Device(s) 
1.  From the Z-Wave devices screen, press DELETE next to the name of the device to delete. Note: The device will be removed 
from the list. 
Troubleshooting 
The Module D
oesn’t Auto Configure or Appear Operational  
• 
Verify the module is installed in the panel correctly and that the pins on the circuit board are aligned properly with the header 
on the Z-Wave module. 
• 
Verify the Z-Wave devices appear in the Z-Wave device list and a green dot appears. Re-install devices if necessary. If these 
steps fail, try replacing the module devices or contact Interlogix Technical Support. 
• 
If a device does not seem to work with an application,  verify that it works at a low level and is a known category device, press 
CONFIGURATION/TESTING/Z-WAVE. Select the device in question and select ON. If the device turns on, it is a known 
category device, but it is not a preferred device. Only known/preferred devices work with the Advisor applications. If the device 
did not turn on, then it is a hardware issue and repeat the steps above or the category device is unknown. 
Unable to Add a Z-Wave Device 
• 
Verify the device has factory defaults and/or has not been learned into another Z-Wave controller. To correct, utilize the reset 
option in step 5D in the section “To Add Z-Wave Device(s)”.   
• 
Verify that the Z-Wave device is a known category device and is on the supported devices list. For more information, contact 
Interlogix Technical Support. 
• 
Replace the device. 
Unable to See Devices in the Application When Launched 
• 
Verify that the user has permission to access the Z-Wave devices.  
• 
Some applications may require permission from the Z-Wave devices to operate properly.  In this instance, log in with an access 
code and attempt to access the Z-Wave device application.  
• 
If the system has multiple partitions, ensure the TouchScreen and user permissions/access match (or are at least a superset) 
the devices’ permission/access. For example, if a secondary Advisor TouchScreen is assigned to partitions one and two, but a 
Z-Wave module is assigned to partition three, then the application will be unable to access or display information. 
• 
If a device does not seem to work with an application,  verify that it works at a low level and is a known category device, press 
CONFIGURATION/TESTING/Z-WAVE. Select the device in question and select ON. If the device turns on, it is a known 
category device, but it is not a preferred device. Only known/preferred devices work with the Advisor applications. If the device 