Restart and Recovery
CMRU
Central Main Replaceable Unit
An RBS has one CMRU.
DMRU
Distributed Main Replaceable Unit
A Main RU is distributed if it is
subordinated to the CMRU.
35.3
Function
35.3.1
Purpose
The entire RBS is brought into operation in a controlled manner. The
sequence of events is given below.
35.3.2
Description
The sequence of actions initiated is summarized below:
1
start CMRU-processor
2
start DMRU-processor
3
start Sub RU-processor (if any)
4
start CMRU basic functions
5
start DMRU basic functions
6
start Sub RU basic functions
7
conditional RBS DB(Data base)load
8
read parameters for OM bus
9
define OM address
10
link establish functions for Sub RUs connected to DMRU
11
link establish functions for Sub RUs connected to CMRU
12
update RBS database for Sub RUs connected to CMRU
13
link establish functions for all expected DMRUs
14
update RBS database for all expected DMRUs
15
update RBS database for Sub RUs connected to DMRU
16
wait for expected Passive RUs
17
internal configuration
18
check RBS operational ability
19
set fault indicator on all DMRUs with faults
20
set operation indicator on all DMRUs with no faults
21
set fault indicator on all Sub RUs with faults
22
set fault indicator on all DMRUs with faults
23
bring CMRU into remote operation