Ericsson Radio Systems AB PKRC1311004-1 Manual De Usuario

Descargar
Página de 423
Operation and Maintenance Support
38.24
Local Mode in Progress
Local Mode in Progress is a subfunction.
Purpose
To change RU mode from Remote to Local.
Preconditions and Initiation
The RU mode should be "Change to Local Mode in progress". The
subfunction will be initiated when a change of RU mode to Local mode
has been initiated.
Description
An external condition class 1, called switch information, is raised on the
RU.
A Fault Report message is sent to the BSC on the Abis interface to
inform the BSC that the unit is taken into Local operation. The RU
mode for the cabinet is changed to Local when the Abis fault report
procedure is terminated.
When Local Mode has been entered, the layer 2 communication links in
Abis interface concerning the SO are released and stopped by RBS
(refer to the Terrestrial Link Handling functionality).
On the TRU, the MO TX and MO TS are disabled if they were
enabled. The TX Not Enabled indicator is turned on.
The function is terminated when the layer 2 communication links on
Abis interface concerning the SO has been released and stopped and
Local mode has been entered.
EN/LZT 720 0008
R1A
2001-06-26
299 (421)
© Ericsson Radio Systems AB
— All Rights Reserved —