Ericsson Radio Systems AB PKRC1311004-1 Manual De Usuario

Descargar
Página de 423
Installation Data Handling
RU Physical Position
Identifies the location of the RU at a site, including information about
cabinet, rack, shelf and slot.
Access:
BSC via the Abis interface (in fault
reports and hardware information)
Operator via the OMT
39.4.3
Elements Found in the RU Database
RU Specific
Includes the parameters specific to an RU. These parameters are
dependent on the hardware design.
39.5
Functions
There are a number of functions and services connected to the
Installation Database Handling. Some examples follow:
39.5.1
Read/Install the RBS Database
The entire RBS database can be both read and written. These functions
are used when the RBS database needs to be transferred between the
OMT and the RBS.
39.5.2
Read Hardware Information
This function makes it possible for the BSC to read detailed information
from the hardware installed in the RBS, for example:
Product number
Revision
Serial number
Physical position
39.5.3
Read Information Element
This function allows the RBS to read information elements in the RU
and RBS databases.
39.5.4
Write Information Element
This function makes it possible for the RBS to write information
elements in the RU and RBS databases.
39.6
Operational Conditions
A reading of the entire RBS database from the RBS to the OMT takes
less than four minutes.
An installation of the entire RBS database, from the OMT to the RBS,
takes less than four minutes.
EN/LZT 720 0008
R1A
2001-06-26
303 (421)
© Ericsson Radio Systems AB
— All Rights Reserved —