Climate Protection
Fault class
There are two possible severity
classifications
Antenna instance number
Defines the physical antenna
Each of these parameters is initially defined manually on RBS
installation, using an OMT. Subsequently any of these parameters may
be modified using an OMT.
The RBS supervises each configuration auxiliary fault. An auxiliary
fault is filtered, that is, must remain in a new state a fixed period of
time (approximately 3 seconds) before the BSC is notified.
The detected fault is reported by sending of a fault report for the
concerned MO(s) over the Abis interface according to the "Diagnostic
and Fault Handling" function. Which MO class and instance to report
the fault on, is derived from the ARAE supervision parameters, receiver
diversity configuration and radio configuration.
The BSC will then take the affected MO(s) out of operation, if
appropriate.
44.4
Operational Conditions
44.4.1
Operation and Maintenance
Maintenance functions related to auxiliary faults are described within
the context of Operation and Maintenance Terminal.
The visual indicators relevant to auxiliary faults are described are
described within the context of Operation and Maintenance Support.
44.4.2
Capabilities
The alarm inlets are used both for external alarms and supervision of
ARAE faults.
The capabilities of the different Radio Base Stations are shown in the
table below:
Table 124
Maximum number of auxiliary faults defined by the customer
Radio Base Station
Auxiliary
Faults,
Maximum
RBS 2101
8
RBS 2102
16
RBS 2103
16
RBS 2202
16
336 (421)