5.7.1.  ACS Message Format 
 
 !-- ACS,x,xxxxxxxxx, hhmmss.ss,xx,xx,xxxx*hh<CR><LF> 
 
 field   1         2          3  4  5    6 
 
Field 
Format 
Description 
Sequence Number , 0 to 9 
xxxxxxxxx 
MMSI of originator 
hhmmss.ss 
UTC of receipt of channel management information 
xx   
UTC Day, 01 -31 
xx   
UTC Month, 01 -12 
6 xxxx  UTC 
Year 
 
 
 
5.8  AIS Alarm Messages (NMEA 0183 ALR, Text) 
Local alarm condition and status. This sentence is used to report an alarm condition on a device and its current 
state of acknowledgement. 
 
 
5.8.1 
ALR message format  
 !-- 
ALR,hhmmss.ss,xxx,A,A,c--c*hh<CR><LF> 
 
field           1   2 3 4    5 
 
Field 
Format 
Description 
hhmmss.ss = Time of alarm (UTC) 
 
Unique alarm number 
3  
Alarm 
condition 
 
Alarm acknowledge state 
 
alarm description, text 
Alarms descriptions presented are: 
 
AIS: TX malfunction 
 
AIS: Antenna VSWR exceeds limit 
 
AIS: Rx channel 1 malfunction 
 
AIS: Rx channel 2 malfunction 
 
AIS: general failure 
 
AIS: no sensor position in use 
 
AIS: no valid SOG information 
 
AIS: no valid COG information 
 
AIS: 12V alarm 
 
AIS: 5V alarm 
 
AIS: Loss of serial interface integrity 
 
AIS: Background noise above -77dBm 
 
5.9 
ACK messages  
 
Can be generated by a minimum keypad and display (MKD) unit, chart plotter or other display device connected 
to the NAUTICAST-B to acknowledge an alarm condition reported by the NAUTICAST-B. 
 
 
5.9.1 
ACK message format 
 
!-- ACK,xxx*hh <CR><LF> 
 
field     1 
 
Field 
Format 
Description 
1 x 
unique 
alarm 
number