Andrew Wireless Innovations Group RPT-MMR8L Manual De Usuario

Descargar
Página de 42
 
User’s Manual for Remote Unit 
MMR8L L
 
Page 38 
 
M0106ASB.doc 
 
8.2. SPECIFICATIONS 
8.2.1. Electrical Specifications 
 
MMR8L L 
Mains power 
100 to 240 Vac 
36 to 72 Vdc 
Power Supply 
Power consumption 
180 W 
Interface 
Number of connectors 
1 single duplexed RF port 
BTS Interface 
Input power  
Micro: 33/43 dBM typical 
Connector 
N Female or DIN 7/16 
Antenna Port 
Return loss 
15 dB 
Connectors E2000/APC 
8° 
Optical return loss 
45 dBm minimum 
Fiber type 
Single mode E9/125 µm 
Optical link budget 
0 to 10 dB 
Optical link 
Composite input power @ 
OTRX master side 
+4 dBm maximum  
System supervision and control 
Commands 
RF on/off; External control ports 
Alarms 
Summary 
Power supply 
Optical UL and DL failure 
RF UL and DL failure 
Temperature 
Door open 
Supervision 
Composite output power 
Frequency ranges 
Nominal 20 dB Bandwidth 
51 MHz 
800 MHz band 
LMR 
UL: 806 to 824 MHz 
DL: 851 to 869 MHz 
Mean rated output power 
1)
 40 
dBm 
@ 1 carrier 
40 dBm 
3)
 Analog; 40 dBm 
3) 
iDEN; 
40 dBm TDMA/ EDGE; 40 dBm 
3)
 
CDMA; 38 dBm 
3) 
WCDMA 
@ 2 carriers 
37 dBm 
3) 
Analog; 37 dBm 
3) 
iDEN; 
37 dBm 
3) 
TDMA/ EDGE;  
35 dBm 
3) 
CDMA; 35 dBm 
3) 
WCDMA 
@ 4 carriers 
34 dBm 
3) 
Analog; 34 dBm 
3) 
iDEN 
34 dBm 
3) 
TDMA/ EDGE; 
32 dBM 
3) 
CDMA; 32 dBm 
3) 
WCDMA 
Output power 
2)
 
@ 8 carriers 
31 dBm 
3) 
Analog; 31 dBm 
3) 
iDEN 
31 dBm 
3) 
TDMA/ EDGE 
29 dBm 
3) 
CDMA; 29 dBm 
3) 
WCDMA 
Intermodulation distance 
-60 dBc