Intel 2860QM FF8062701065100 Manual De Usuario

Los códigos de productos
FF8062701065100
Descargar
Página de 96
Datasheet 
75
Thermal Specifications
6.1.2
Thermal Metrology
The minimum and maximum TTV case temperatures (T
CASE
) are specified in 
an
 and are measured at the geometric top center of the thermal test vehicle 
integrated heat spreader (IHS). 
 illustrates the location where T
CASE
 
temperature measurements should be made. For detailed guidelines on temperature 
measurement methodology and attaching the thermocouple, refer to the appropriate 
processor Thermal and Mechanical Design Guidelines (see 
Notes:
1.
Figure is not to scale and is for reference only.
2.
B1: Max = 45.07 mm, Min = 44.93 mm.
3.
B2: Max = 42.57 mm, Min = 42.43 mm.
4.
C1: Max = 39.1 mm, Min = 38.9 mm.
5.
C2: Max = 36.6 mm, Min = 36.4 mm.
6.
C3: Max = 2.3 mm, Min = 2.2 mm
7.
C4: Max = 2.3 mm, Min = 2.2 mm.
8.
Refer to the appropriate Thermal and Mechanical Design Guide (see 
) for instructions on 
thermocouple installation on the processor TTV package.
Figure 6-2. Thermal Test Vehicle (TTV) Case Temperature (T
CASE