Sanitag Technologies Corporation AT004H Manual De Usuario

Descargar
Página de 23
  
 
Setting Up Devices & RF Netwowk 
 
 
 
 
 
1-5 
 
 
 
 
 
 
 
THIS DOCUMENT IS THE PROPERTY OF SANITAG COMPANY. IT MAY NOT BE COPIED AND REPRODUCED WITHOUT WRITTEN PERMISSION OF SANITAG 
COMPANY. COPYRIGHT NOTICES MAY NOT BE REMOVED 
 
        user is encouraged to try to correct the interference by one or more of the following  
        measures: 
 
       
—Reorient or relocate the receiving antenna. 
       
—Increase the separation between the equipment and receiver. 
       
—Connect the equipment into an outlet on a circuit different from that to which the receiver    
       is connected. 
       
—Consult the dealer or an experienced radio/TV technician for help. 
 
 
1.1.2. 
Active  RFID  Room  Level  Reader  (Sanitag  Model  No:  AR-001-HLR)  & 
Active RFID Long Range Reader (Sanitag Model No: AR-002-HLR) 
 
These  devices  are  hierarchically  below  Router  or  upper  level  Reader  on  network.  It 
collects Mobile Beacon Messages and also sub-level Reader messages and then routes 
them to the upper level Reader or Router. It has also  blue leds on itself.  
 
If leds blink, it means that the reader device searches to join Rf network. So it implies that 
the reader is not joined any Rf network yet. 
 
If leds ligthen constantly, it means that the reader device joins Rf Network succesfully. 
 
Sanitag AR-001-HLR device has RF propagation that 2.5dBm output power level  and  it 
has 2,4 GHz uFl tranmitter antenna which is has  2dBi gain. Sanitag AR-002-HLR device 
has  RF  propagation  that  22dBm  output  power  level  and    it  has  2,4  GHz  uFl  tranmitter 
antenna which is has  2dBi gain. 
 
Also,  AR-001-HLR  and  AR-002-HLR  devices  have  UWB  module  that  has  3.1  ~  8  GHz 
monopole antenna. We operation  at 4.4GHz due to special reason. UWB Module output 
power is fully adjustable from 0 dBm to 15.5 dBm via firmware. 
 
The  antenna  that  using  on  Sanitag  AR-001-HLR  and  Sanitag  AR-002-HLR  are  wire 
antenna  which  is  fixed  on  PCB,  That's  why  İt  cannot  change  reorient  and  relocate
.
The 
device's  antenna  type  is  omnidirectional.  Therefore,  the  Sanitag  AR-001-HLR  and 
Sanitag AR-002-HLR can take signal every direction. 
İf devices obstruct by obstacle of in 
Table 1.  The 
device’s RF signal will decrease as stated in Table 1. 
 
 
          THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS              
          SUBJECT TO THE FOLLOWING TWO CONDITIONS. 
 
         (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS     
         DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING    
         INTERFERENCE   THAT MAY CAUSE UNDESIRED OPERATION. 
 
         Warning: Changes or modifications not expressly approved by the party responsible for  
         
compliance could void the user’s authority to operate this equipment.  
 
         Note: This equipment has been tested and found to comply with the limits for a Class B   
         digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide