• Do not install in places with open fl ames or fl ammable gas.
• Do not use extension cords etc. Only plug the indoor unit into a grounded wall outlet.
• Install in clear area without any obstructions nearby.
• Avoid installing the indoor unit in damp areas.
• Install near the wall with space to link the coolant lines between the indoor and outdoor
unit.
OUTDOOR UNIT
• Never install the outdoor unit in a place where the product is likely to fall.
• Make sure to drain the outdoor unit with the drainage pipe.
• Do not install the outdoor unit in direct sunlight.
• Do not install the outdoor unit near open fl ames or by fl ammable gas.
• Do not install the outdoor unit in extremely windy areas.
1.4 – FCC Information
DECLARATION OF CONFORMITY:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
FCC RELATED INFORMATION:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit diff erent from that to which the
receiver is connected.
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifi cations to this equipment. Such modifi cations could void the user’s authority to operate
the equipment.
modifi cations to this equipment. Such modifi cations could void the user’s authority to operate
the equipment.
1.5 – Disposal at End-of-Life
This product must not be disposed of by incineration, landfi lling, or mixing with household
trash. Improper disposal of the battery contained within this product may result in the battery
heating up, rupturing, or igniting which may cause serious injury. The refrigerants contained
inside the RolliCool present chemical risks to the environment. The recommended disposal
for any RolliCool Portable Air Conditioner at its end-of-life is to dispose of the entire unit by
contacting your local recycling company. Local regulations and laws pertaining to the recycling
trash. Improper disposal of the battery contained within this product may result in the battery
heating up, rupturing, or igniting which may cause serious injury. The refrigerants contained
inside the RolliCool present chemical risks to the environment. The recommended disposal
for any RolliCool Portable Air Conditioner at its end-of-life is to dispose of the entire unit by
contacting your local recycling company. Local regulations and laws pertaining to the recycling
19
RolliBot RolliCool Mini-Split AC User Manual
•
When a schedule is active, the unit will not turn on if the chosen temperature is higher than the indoor temperature.
TO SET A SHUTOFF TIME
1. When the unit and remote are on, press the Timer Button on the Control Panel or the remote.
2. Use the Up and Down Buttons to select the time the AC unit will turn off i.e. selecting “03” will
prompt the unit to turn off in 3 hours’ time etc.
3. After the selection is complete, the display will show the current indoor temperature and the
Schedule Light.
Section 6. Maintenance
Proper maintenance will help improve your RolliCool’s performance. The RolliCool will
periodically need its fi lter cleaned. For optimal performance, the fi lters should be cleaned at
least twice a month. It is also recommended to regularly inspect the Drainage Pipe.
periodically need its fi lter cleaned. For optimal performance, the fi lters should be cleaned at
least twice a month. It is also recommended to regularly inspect the Drainage Pipe.
If any type of non-routine maintenance is needed, such as any maintenance not described in Section 6 of this manual,
please contact customer service or a certifi ed HVAC professional as the unit contains refrigerant.
please contact customer service or a certifi ed HVAC professional as the unit contains refrigerant.
6.1 – How to Clean the Filters
•
Please make sure your AC unit is completely powered off before performing any type of maintenance.
•
Do not scrape the air fi lters as it may sustain damage.
•
A hand vacuum or low-powered vacuum or vacuum modes may be used to clean the fi lters.
•
Replace the fi lters after cleaning. Do not use the RolliCool without the fi lters.
1. Pull off the front
panel.
2. Pull out the fi lter.
1
2
1
2
Rollibot-MiniSplitAC-UM-0403.indd Spread 6 of 12 - Pages(6, 19)
Rollibot-MiniSplitAC-UM-0403.indd Spread 6 of 12 - Pages(6, 19)
4/10/2017 7:41:19 PM
4/10/2017 7:41:19 PM