Iotek Systems LLC HXC900 Manual De Usuario
HXC Client Module User Guide
Version 1.09
© 2017 All rights reserved. Iotek Systems, LLC
Page 25 of 59
AT+DEVEUI=8899aabbccddeeff
>>>
OK
Users can receive AT_PARAM_ERROR if the parameter has less than 16 digits (8 bytes).
AT+DEVEUI=8899aabbccddee
>>>
AT_PARAM_ERROR
Users can receive AT_BUSY_ERROR if this command is used during a LoRa transmission
(Join, Data Send or Continuous Tx). The user will have to wait till the transmission is
(Join, Data Send or Continuous Tx). The user will have to wait till the transmission is
done.
AT+DEVEUI=11de45ad0000face
>>>
AT_BUSY_ERROR
Users can receive AT_BUSY_ERROR during AUTO command if the processor fails to read
the EUI64 bytes.
the EUI64 bytes.
AT+DEVEUI=AUTO
>>>
AT_BUSY_ERROR
8.7.2.2 AT+DEVADR: Device Address
This command allows users to access the device address. Default value is 00:00:00:00.
OTAA authentication scheme will provide the DEVADR during JOIN procedure. During
ABP, the user will have to define the DEVADR. The command takes 8digit (4byte) hex
value. Hex values are case-insensitive. Any change of DEVADR using Set command is
ABP, the user will have to define the DEVADR. The command takes 8digit (4byte) hex
value. Hex values are case-insensitive. Any change of DEVADR using Set command is
saved in EEPROM and can be retained after a Reset.
Format: AT+DEVADR = <param>
Format: AT+DEVADR = <param>
AT+DEVADR?
>>>
Get or Set Device Address
>>>
OK
AT+DEVADR=?
>>>
00:00:00:00
>>>
OK
AT+DEVADR=112233AA
>>>
OK
Users can receive AT_PARAM_ERROR if the parameter has less than 8 digits (4 bytes).
AT+DEVADR=112233A
>>>
AT_PARAM_ERROR