GAMDIAS Technology Co. Ltd. HADESM1 Manual De Usuario

Descargar
Página de 8
                                                                                                                                  TG-RD-002A0 
 
7.3
Switch Life Test
 
Switching speed:
 
 
                      1 cycle/sec; 
Operating force : 
 
 
              75 ±30 gf-cm; 
Operating cycles
:   
 
              200,000 cycles; 
7.4
High Temperature Test   
 
Temperature
:                                60±2
o
C; 
Time: 
                  96 hours; 
After this test the mouse shall be left in room temperature for 1 hour. 
7.5
Low Temperature Test     
 
Temperature
:                                      -15±2
o
C; 
Time:                                96 hours; 
After this test the mouse shall be left in room temperature for 1 hour. 
7.6 Moisture Test 
Temperature
:   
                                40±2
o
C; 
Humidity: 
 
                                90~95% R.H.; 
Time:                                96 hours; 
After this test the mouse shall be left in room temperature for 1 hour. 
7.7   
Temperature
:   
                          -15±2
o
C for 1 hour and then 60±2
o
C for 1 hour; 
Operating cycles: 
 
                          5 cycles;   
After this test the mouse shall be left in room temperature for 1 hour. 
7.8 
Drop Test
 
Times of Drops: 
 
 
 
 
          6    times; 
Height:         
   
 
 
          70±5 cm; 
Direction:   
 
 
 
 
                  5 
faces.
 
Floor surface: 
   
 
 
 
          Plastic floor tile; 
7.9 Wire swing test 
Swing speed   
 
 
 
30 cycle/min; 
Load:    
 
 
 
        100 g; 
Swing angle: 
 
 
 
   
±60°; 
Swing times: 
 
 
 
 
8000 (Min.);