GAMDIAS Technology Co. Ltd. HADESM1 Manual De Usuario
TG-RD-002A0
7.3
Switch Life Test
Switching speed:
1 cycle/sec;
Operating force :
75 ±30 gf-cm;
Operating cycles
:
200,000 cycles;
7.4
High Temperature Test
Temperature
: 60±2
o
C;
Time:
96 hours;
After this test the mouse shall be left in room temperature for 1 hour.
7.5
Low Temperature Test
Temperature
: -15±2
o
C;
Time: 96 hours;
After this test the mouse shall be left in room temperature for 1 hour.
7.6 Moisture Test
Temperature
:
40±2
o
C;
Humidity:
90~95% R.H.;
Time: 96 hours;
After this test the mouse shall be left in room temperature for 1 hour.
7.7
Temperature
:
-15±2
o
C for 1 hour and then 60±2
o
C for 1 hour;
Operating cycles:
5 cycles;
After this test the mouse shall be left in room temperature for 1 hour.
7.8
Drop Test
Times of Drops:
6 times;
Height:
70±5 cm;
Direction:
5
faces.
Floor surface:
Plastic floor tile;
7.9 Wire swing test
Swing speed
30 cycle/min;
Load:
100 g;
Swing angle:
±60°;
Swing times:
8000 (Min.);