Gosuncn Technology Group Co. Ltd. GM500U1A Manual De Usuario

Descargar
Página de 64
 
All Rights reserved, No Spreading abroad without 
GOSUNCN
 Permission 
 
 
56 
 
GM500_U1A 
Hardware  Development  Guide 
6. R
ELATED 
T
EST 
&
 
T
EST 
S
TANDARD
 
6.1. T
ESTING 
R
EFERENCE
 
The  related  tests  of  MODULE  comply  with  the  IEC  standard,  including  the  equipment  running  under  high/low  temperature, 
storage  under  high/low  temperature,  temperature  shock  and  EMC.  Table  6-1  is  the  list  of  testing  standard,  which  includes  the 
related testing standards for MODULE.   
Table 6-1    Testing Standard
 
NOTE: 
  IEC: International Electro technical Commission;   
  GB/T: Recommended national standard   
Test Standard 
Document Reference 
IEC6006826 
Environmental testing-Part2.6: Test FC: Sinusoidal Vibration 
IEC60068234 
Basic environment testing procedures part2. 
IEC60068264 
Environmental testing-part2-64: Test FH: vibration, broadband random and guidance. 
IEC60068214 
Environmental testing-part 2-14: Test N: change of temperature 
IEC60068229 
Basic environmental testing procedures-part2: Test EB and guidance. 
IEC6006822 
Environmental testing-part2-2: Test B:dry heat 
IEC6006821 
Environment testing-part2-1: Test A: cold. 
GB/T 15844.2 
MS telecommunication RF wireless phone-set environment requirement & experimental method – part 4: Strict level of 
experimental condition 
GB/T 2423.17 
Basic environment experiment of electronic products-Experiment Ka: Salt mist experiment method 
GB/T 2423.5 
Basic environment experiment of electronic products-Part2: Experiment method Try Ea & Introduction: Shock 
GB/T 2423.11 
Basic environment experiment of electronic products-Part2: Experiment method Try Fd: Broad frequency band random vibration 
(General requirement) 
TIA/EIA 603 3.3.5 
TIA Standard-part3-5:Shock Stability   
 
6.2. D
ESCRIPTION OF 
T
ESTING 
E
NVIRONMENT
 
The working temperature range of MODULE is divided into the normal working temperature range and the extreme working 
temperature range. Under the normal working temperature range, the testing result of RF complies with the requirements of 3GPP 
specifications,  and  its  function  is  normal.  Under  the  extreme  temperature  range,  the  RF  index  basically  complies  with  the  3GPP 
specifications, and the quality of data communication is affected to a certain extent, but its normal function is not affected. MODULE 
has  passed  the  EMC  test.  Table  6-2  is  the  requirement  for  the  testing  environment,  and  Table  6-3  lists  out  the  instruments  and 
devices that might be used during the test.   
WARNING:   
Table 6-2 lists the extreme working conditions for the Module. Using the Module beyond these conditions 
may result in permanent damage to the module. 
Table 6-2    Testing Environment 
Working Condition 
Min Temperature 
Max Temperature 
Remark