being stored more than a year in order to activate it and restore energy. 
长期储存电池时,应符合
3.12
条款的要求。为防止电池过放,建议每
3 个月进行一次充电,如
储存时间超过一年,建议每年进行一次充、放电以激活电池
5.2    Do not use the battery in a location where static electricity and magnetic field is great, 
otherwise, the safety devices may be damaged, causing hidden trouble of safety. 
禁止在强静电和强磁场的地方使用
,否则易破坏电池安全保护装置,带来不安全的隐患 
5.3    Any issues not covered in this specification should be discussed between the customer and 
GREEN ENERGY.  
 
本说明书中未提及的任何事项,须经双方协商确定。
 
6. Repair period  包修期限     
The repair period is 6 months from the data that the batteries are shipped out from the factory (the 
printing date on the cell). 
产品包修期限为
个月,自出厂日期(喷码)开始算起。 
 
7. Protection circuit  保护电路 
  7.1 Electrical characteristics  电气特性 
Item 
项目
 
Content 
详细内容
 
Criterion 
标准
 
Over charge Protection 
过充保护
 
Single Over-Charge Voltage Protection 
单体过充保护电压
 
 3.65±0.05V 
Over-Charge detection delay time 
过充电检测延迟时间
 
<3000ms 
Over charge release voltage
过充电解除电压
 
3.45±0.05V 
Over discharge protection 
过放保护
 
Single Over-Discharge Voltage Protection
单体过放保护电压
 
2.5±0.05V 
Over-Discharge detection delay time 
过放电检测延迟时间
 
<3000ms
 
Over discharge release voltage
过放电解除电压
 
2.70±0.05V 
Over current protection 
过流保护
 
Over-Current Discharge Protection 
放电保护电流
 
27A~33A 
Detection delay time
检测延迟时间
 
<65ms
 
Short protection 
短路保护
 
Short Protection Detection delay time
短路保护检测延迟时间
 
<2ms 
Balanced 
均衡
 
Equalization starting voltage
均衡启动电压
 
3.8V 
Equalizing current
均衡电流
 
45mA 
Interior resistance 
内阻
 
Internal resistance in normal operation 
P+,P-导通内阻 
≤50mΩ 
Current consumption 
消耗电流
 
Current consume in normal operation   
正常工作时消耗电流
 
<1mA