Cambricon Technologies Corporation Limited MLU100-C Manual De Usuario

Descargar
Página de 12
Cambricon, MLU100-C Series Intelligent Processing Card User Manual, 2018-09 
 
 
Table 4 SMBUS Registers Description   
2.3 
Working Environment Specifications 
 
Operating Temperature 
0℃~45°C 
Storage Temperature 
-
40℃~75℃ 
Operating Humidity 
5%—95% Relative Humidity 
Storage Humidity 
5%—95% Relative Humidity 
Table 5 PCIE Card Working Environment 
2.4 
Outline Dimension Specifications 
 
Figure 2 MLU100-C outline dimension 
2.5 
Heat Dissipation Specifications 
MLU100-C Series Intelligent Processing Card is using a passive heat dissipation method. The system 
designers should pay attentions to below for the Airflow Volume at the entrance and Temperature 
of Ambient relationship, so as to design a cooling system for the card and guarantee the card is 
operating within the green recommendation area. The core clock frequency of the chip will be 
decreased to half when the temperature of chip is over 87
℃, and shut down when over 90℃. 
 
Vendor Name 
0xF1 
RO 
 
Hardware Revision 
0xF2 
RO 
 
Firmware Revision 
0xF3 
RO 
 
Manufacturing Time 
0xF4 
RO 
 
Device ID 
0xF5 
RO