5 Set Power Dialogue
Depending on the environment and the RFID tag in use, you need to adjust the power setting
of the reader's amplifier to read and write successfully.
of the reader's amplifier to read and write successfully.
5.1 To set the power level
•
Select “Settings->Set Power” from the top menu bar
•
Use the slide bar to set the power level
•
Click on “OK”
Output power range:
Min = 10 dbm
Max = 22 dbm
Stepping = 1 dbm
Max = 22 dbm
Stepping = 1 dbm
GTSYS LTD. 23/F Heng Shan Centre, 145 Queen's Road East, Wan Chai, HONG KONG SAR – Email: sales@gtsys.com.hk
Copyright © 2011 GTSYS – GTSYS reserves the right to change specifications without prior notice
Page 9 / 11
Notice: High power values can have a negative effect to the read/write results – it is recommend to start
from low (min) to high (max) power values in small steps to find the optimal setting.