15
4.
PROCEDURE FOR RETROFIT
4.1
Required Tools and a Part for Retrofit
Below tools are required for retrofit. A rubber gasket is required for retrofit.
•   Positive and negative screwdrivers
•   Rubber gasket (two holes) provided as an optional kit
•   A fuse with below characteristics is required for retrofit. Local supply.
Current rating: 5A, Voltage rating: 32V, Cable Diameter 12AWG (2.053 mm)
•  Refer to the below table about the limitation of cable length according to the ship’s 
main supply.
4.2
Retrofit Procedures
Note 1: Retrofit from DRS2D, DRS4D and DRS6A is available with below procedures.
Note 2: Below procedures are for using a 5A fuse.
Note 3: Make sure that the multi function display device is turned off and the two-way 
cable MOD-ASW0001 is unplugged from the multi function display device and the 
power supply unit before starting below procedures.
Procedures for the radome
1. Put the radome upside down.
2. Unfasten six retaining screws at the bottom of radome and open it.
Ship’s Main Supply
Limitation on Cable Length
10.8 VDC
Unavailable
12 VDC
Less than 10 m only
24 VDC
No limitation