ICOM 329600 Manual De Usuario

Descargar
Página de 72
2001 NEW
44
5
MENU SCREEN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Quic
k Ref
erence
ALE BER Threshold
Set the Bit Error Ratio (BER) threshold level to be-
tween 0 and 48 bits for ALE communication quality.
 
(Default: 12)
One unit consists of 48 bits of data.
ALE Golay Threshold
Set the Golay threshold level to between 0 and 3 bits 
for ALE communication quality.  
(Default: 3)
The Golay consists of 12 bits of original data and 12 
bits of correction data.
ALE Silent
Set the ALE Silent mode ON or OFF.
 
(Default: OFF)
When set to OFF, the transceiver automatically an-
swers back if your station ID is called. When set to 
ON, the transceiver ignores the call.
ALE Error Threshold
Set the Error threshold level to between 0 and 4 for 
ALE communication quality.
 
(Default: 0)
When  errors  detected  by  BER  threshold  or  Golay 
threshold are over this setting, communication is not 
possible.
ALE Call Retry
Set the retry times to between 0 (OFF) and 99 when 
the called station does not answer back.  (Default: 0)
ALE Decay Time
Set the decay time for the Auto Sounding function to 
between 1 and 8 hours. 
(Default: 1 hour)
ALE Sounding Length
Set  the  signal  length  to  between  5  words  and  100 
words, in 1 word steps. 
(Default: 5 words)
The transceiver repeats to call a calling ID during this 
setting length.