ICOM IC-756PRO2 Manual De Usuario

Descargar
Página de 88
82
13
CONTROL COMMAND
• Command table
Command
Sub command
Description
00
Send frequency data
01
Same as 
Send mode data
command 06
02
Read band edge frequencies
03
Read operating frequency
04
Read operating mode
05
Set frequency data
00
Set LSB
01
Set USB
02
Set AM
06
03
Set CW
04
Set RTTY
05
Set FM
07
Set CW-R
08
Set RTTY-R
Select VFO mode
B0
Exchange main and sub readouts
B1
Equalize main and sub readouts
07
C0
Turn the dualwatch OFF
C1
Turn the dualwatch ON
D0
Select main readout
D1
Select sub readout
Select memory mode
08
0001–0101*
1
Select memory channel
*
1
P1=0100, P2=0101
09
Memory write
0A
Memory to VFO
0B
Memory clear
00
Scan stop
01
Programmed/memory scan start
02
Programmed scan start
03
F scan start
12
Fine programmed scan start
13
Fine 
F scan start
22
Memory scan start
0E
23
Select memory scan start
A1–A7
Set 
F scan span (A1=±5 kHz,
A2=±10 kHz, A3=±20 kHz,
A4=±50 kHz, A5=±100 kHz,
A6=±500 kHz, A7=±1 MHz)
B0
Set as non-select channel
B1
Set as select channel
D0
Set scan resume OFF
D3
Set scan resume ON
0F
00
Turn the split function OFF
01
Turn the split function ON
00
10 Hz (1 Hz) tuning step
01
100 Hz tuning step
02
1 kHz tuning step
03
5 kHz tuning step
10
04
9 kHz tuning step
05
10 kHz tuning step
06
12.5 kHz tuning step
07
20 kHz tuning step
08
25 kHz tuning step
11
00
Attenuator OFF
06
Attenuator ON (6 dB)
12
Attenuator ON (12 dB)
18
Attenuator ON (18 dB)
12
00
Select [ANT1]
01
Select [ANT2] 
(Add 0 or 1 to turn [RX ANT] OFF
or ON, respectively.)
Command
Sub command
Description
00
Announce with voice synthesizer
13
01
(00=all data; 01=frequency and 
02
S-meter level; 02=receive mode)
01 + Level data
[AF] level setting (0=max. CCW to
255=max. CW)
02 + Level data
[RF] level setting (0=max. CCW to
255=max. CW)
03 + Level data
[SQL] level setting (0=11 o’clock to
255=max. CW)
06 + Level data
[NR] level setting (0=min. to
255=max.)
07 + Level data
Inside [TWIN PBT] setting or IF
shift setting (0=max. CCW,
128=center, 255=max. CW)
08 + Level data
Outside [TWIN PBT] setting 
(0=max. CCW, 128=center,
255=max. CW)
14
09 + Level data
[CW PITCH] setting (0=low pitch to
255=high pitch)
0A + Level data
[RF POWER] setting (0=mini. to
255=max.)
0B + Level data
[MIC GAIN] setting (0=mini. to
255=max.)
0C + Level data [KEY SPEED] setting (0=slow to
255=fast)
0D + Level data [NOTCH] setting (0=low freq. to
255=high freq.)
0E + Level data
[COMP] setting (0=mini. to
255=max.)
0F + Level data
[BK-IN DELAY] setting (0=short
delay to 255=long delay)
10 + Level data
[BAL] level setting (0=max. CCW,
128=center, 255=max. CW)
15
01
Read squelch condition
02
Read S-meter level
02
Set preamp (0=OFF; 1=preamp 1;
2=preamp 2)
12
Set AGC time constant (1=FAST;
2=MID; 3=SLOW)
22
Set noise blanker (0=OFF; 1=ON)
40
Set noise reduction (0=OFF; 1=ON)
41
Set auto notch (0=OFF; 1=ON)
42
Set repeater tone (0=OFF; 1=ON)
16
43
Set tone squelch (0=OFF; 1=ON)
44
Set speech compressor 
(0=OFF; 1=ON)
45
Set monitor (0=OFF; 1=ON)
46
Set VOX function (0=OFF; 1=ON)
47
Set break-in (0=OFF; 1=ON)
48
Set manual notch (0=OFF; 1=ON)
49
Set RTTY filter notch 
(0=OFF; 1=ON)
19
00
Read the transceiver ID
00
Send/read memory contents
1A
01
Send/read band stacking register
contents
02
Send/read CW keyer contents
1B
00
Set repeater tone frequency
01
Set tone squelch tone frequency
1C
00
Set the transceiver to receive or
transmit condition (0=Rx; 1=Tx)