Shanghai Senben Lighting Technology Company HUNHE40 Manual De Usuario
User manual
FCC ID: 2AA55HUNHE40
For Model: SBD1103-YQL40;
For Model: SBD1103-YQL40;
SBF6103-YQL40;
SBD1110-YQL40;
SBF6107-YQL40;
SBD1110-YQL40;
SBF6107-YQL40;
1. use
Shanghai Senben Lighting Technology Incorporated Company’s SBD1103 SBF6103/SBD1110/SBF6107
Maintenance-free, Energy-saving, Waterproof, Dustproof and Corrosion-proof Factory Lamp, the light source
Maintenance-free, Energy-saving, Waterproof, Dustproof and Corrosion-proof Factory Lamp, the light source
is induction lamp, and has the high Luminous Efficiency, longer lifespan etc features, the luminaire adopts the
integrated structure, aluminum alloy die-casted ballast box and incoming line cover with the surface painted with
polyester powder, This product is applicable for the common lighting or emergency lighting of such indoor and
outdoor place with mech dust or damp such as factory ,airport,tunnel,especially power plant and its boiler
unit,iron& steel plant and so on.
integrated structure, aluminum alloy die-casted ballast box and incoming line cover with the surface painted with
polyester powder, This product is applicable for the common lighting or emergency lighting of such indoor and
outdoor place with mech dust or damp such as factory ,airport,tunnel,especially power plant and its boiler
unit,iron& steel plant and so on.
2.Electrical parameters:
1.
Rated Vol.:
120VAC 60Hz
2.
Illuminant: Electromagnetic
induction illuminant
3.
Power: 40 W
4.
Ex marking:
Ex d e II CT4 Gb
Ex tb III C T80℃ Db
5.
IP
code: IP66
6.
Corrosion-proof grade: WF2
7.
Applicable cable outer diameter:
φ 9~12.5mm
8.
Outline and installation size see Figure 1
3. Directions
1.
In order to ensure the safety service of this Ex light, it shall be installed and maintained by trained
personnel. Unauthorized people shall not open or disassembly the fasteners.
personnel. Unauthorized people shall not open or disassembly the fasteners.
2.
Since polyester transparent cover is adopted, there is a waning label: Warning - Potential electrostatic
charge - see Instruction Manual. The installation hight shall no less than 2.5m, user shall pay
attention to the electrostatic charge. Avoid ignition risks caused by normal service, maintenance and
cleaning; do not touch or wipe the light in hazardous areas. Necessary replacement, wiping and touch
shall be carried out in non-hazardous area.
charge - see Instruction Manual. The installation hight shall no less than 2.5m, user shall pay
attention to the electrostatic charge. Avoid ignition risks caused by normal service, maintenance and
cleaning; do not touch or wipe the light in hazardous areas. Necessary replacement, wiping and touch
shall be carried out in non-hazardous area.
3.
Installation and maintenance procedures shall meet associate national standards, do not operate when
energized. Do not open when energized in maintenance or replacement and waiting for the illuminant
to cooldown.
energized. Do not open when energized in maintenance or replacement and waiting for the illuminant
to cooldown.
4.
There must be a designated person to in charge of the maintenance work specially.
a)
a)
Special operational platform, ladder, safety belt and other necessary equipment shall be
equipped to ensure personnel safety;
equipped to ensure personnel safety;
Figure1
1
1
Type A
Type D