CartaSense Ltd. MSENSOR01 Manual De Usuario

Descargar
Página de 64
 
Troubleshooting
 
 
 Installation, Operation & Maintenance of the Wireless Sensing Family 
27 
 
5 Troubleshooting 
5.1  Introduction 
The following practical troubleshooting section is provided as a training resource 
for individuals learning how to install and use the Wireless Sensing Family 
products, and as a reference tool for those already familiar with its use and 
operation. It should be noted that this outline is not all inclusive, and is intended 
only as a guide. 
5.2  Problems 
Problem  
Potential Cause 
Suggested Action 
U-Sensor Gateway does 
not operate 
The USG is not connected to the 
power source for more than 9 hours 
and batteries were depleted. 
Charge batteries until green LED is 
on 
Gateway fails to connect 
for 15 minutes 
  
 
Power off the gateway wait a minute 
and power it on 
Gateway fails to connect 
(after resetting the 
gateway) 
SIM card is not properly configured  
Check the internet connection of the 
SIM by means of a cellular phone 
using the same GPRS parameters. 
Check Gateway connectivity with the 
safe SIM. 
Gateway fails to connect 
(SIM is ok ) 
Network connectivity problems 
Call CartaSense administrator to 
check if the network is operational. 
Gateway fails to connect 
(Network ok) 
Gateway is not configured properly 
to work with that SIM. 
Provide log file of the connection that 
starts since power on and lasts 5 
minutes.  
For creating the log file - refer 
to 1.1.1.1.1Appendix-C:  
 
Tree view shows sensors 
that are no longer 
connected 
USG lost cellular communication, 
therefore it shows the last image 
 
Tree view doesn’t show 
up.  
Status is not updated yet. The tree 
structure is updated every 30 
minutes. 
Wait at least 45 minutes between 
the end of installation and the tree 
view.  
R-Sensor doesn't work 
(no blinking light) 
Batteries are not install properly  
Re-Install batteries. 
Resident Sensor or U-
Sensor doesn’t appear to 
be connected to the 
network. 
Not in range of the USG. 
Verify that sensor led blinks twice 
(not connected). Make sure that 
antenna is open to its full length. 
Bring it close to the GW to verify that 
it is working. Add additional R-
Sensor to cover the specific area.