ƒ U 
 
Æ  Increases power by 0.5 dB  (fine adjustment) 
ƒ C 
Æ Decreases TX power by 0.5 dB  (fine adjustment) 
ƒ Cu 
Æ Increases power by 5 dB  (course adjustment) 
ƒ Cd 
Æ Decreases TX power by 5 dB  (course adjustment) 
o
  Between each adjustment observe the RSSI and MCS value at the 
CPE RX until the desired value is achieved. 
o
  The following commands can be used to read the transmitter  
configuration: 
ƒ  Gettxstatus :  Will show the TX power as well as the value of the 
TXattenuator.   The TX attenuator cannot be accessed using the 
User Interface but is provided for diagnostic purposes. 
Note:  If the User tries to increase the TX power beyond the maximum power 
for which the device has been certified, the software will not allow the TX 
power to be increased beyond the maximum permissible value.    
Furthermore,  for some links it may not be possible to achieve an RSSI of -75 
dBm, at which point the link should be set to transmit at the maximum 
permissible power to get the best RSSI and hence SNR. 
 
 
8.1.2  Point to Multi-Point Link 
  
The power control for a point to multi-point link can be performed in a similar manner 
with a few small but important differences.   The Uplink power control should be 
performed first to ensure that signals from the 2 or more  CPE’s  arrives at the BTS 
at a similar power.  This will prevent the creation of a near far issue for the BTS 
which can severely degrade throughput.    For the Downlink power control,  the BTS 
TX power should be decreased until the CPE with the weakest signal has an RSSI of 
about -75 dBm.  If the furthest CPE cannot achieve an RSSI of -75 dBm when the 
BTS is transmitting at full power,   then the BTS should be configured at full power in 
order to provide a reasonable level of service to the furthest CPE.     
 
It is important to ensure we do not have a very large spread of RSSI’s on the uplink, 
from the multiple CPE’s.  Acceptable values are from Senstivity ( -100 dBm to about 
-70 dBm).   The presence of a strong signal , > -60 dBm will actuate the RX AGC of 
the BTS and will degrade the quality of the connection for CPE’s which are arriving 
at low powers near sensitivity.  If the Uplink power control is performed properly,  the 
signals from all CPE’s should be between -100 dBm and -70 dBm and no near far 
issue will be present.   Ideally, the signal from all CPE’s should be received by the 
BTS at about -75 dBm. 
 
8.1.2.1  Configure the link: 
•  Telnet into the BTS and each of the CPE’s. 
•  From the telnet session type “monitor”