Wire Specification:
Category 5e/Category 6 for use with RJ-45 Connector
24 AWG
Maximum length of wire from Power Distribution Panel to device:
Category 5e/Category 6 for use with RJ-45 Connector
24 AWG
Maximum length of wire from Power Distribution Panel to device:
- 8’ X 8’ Shade with 40:1 motor - 1250’
- 12’ X 12’ Shade with 73:1 motor - 750’
- 12’ X 20’ Shade with 73:1 motor - 500’
- Hardwired 4 and 8 Button Switches - 1000’
*Length based on 115K baud rate
Maximum wire length for RS485 communication - 2000’
Maximum wire length for RS485 communication - 2000’
Power Distribution Panel:
8 RJ-45 ports for motorized shades and switches
2 additional RJ-45 communication ports dedicated to daisy chain with other Power Distribution Panels
8 RJ-45 ports for motorized shades and switches
2 additional RJ-45 communication ports dedicated to daisy chain with other Power Distribution Panels
and Third Party Integration via RS485.
Power Supply
- AC Input: 100-240 VAC, 2.5A
- DC Output: 24 VDC, 7.5A
Note:
Standard Roll Applications (Motor Left) - Wire will need to be run to the LEFT side of the window (as shown).
Reverse Roll Applications (Motor Right) - Wire will need to be run to the RIGHT side of the window .
Standard Roll Applications (Motor Left) - Wire will need to be run to the LEFT side of the window (as shown).
Reverse Roll Applications (Motor Right) - Wire will need to be run to the RIGHT side of the window .
ZigBee Hardwired Roller Shade
Single Hardwired Switch Application
Part #
Part #
24 VDC
Power Supply
Power
Distribution Panel
Hardwired
Switch
ZigBee Hardwired Roller Shade
Third Party Integration
24 VDC
Power Supplies
24 VDC
Power Supplies
Hardwired
Switch
RS485
Communication
NOTE: The QMotion ZigBee Hardwired System does not operate on “standard” Power over Ethernet (PoE)
schemes. Do not attempt to connect the QMotion ZigBee Hardwired System to any Ethernet device. Doing so may
damage the system components and/or the external Ethernet or PoE device.
schemes. Do not attempt to connect the QMotion ZigBee Hardwired System to any Ethernet device. Doing so may
damage the system components and/or the external Ethernet or PoE device.
Caution
Third Party
Integration
Power
Distribution Panels
System Capacity:
200 Devices (QMotion Shades, QMotion Hardwired Switches)
ZigBee
Coordinator/
Router
ZigBee
Remote
*Specifications are subject to change without notice