  Recommended operating conditions 
 
Rating 
Min 
Typ 
Max 
Unit 
Operating Temperature 
-40 
85 
℃ 
VDD 
2.3 
3.0 
3.6 
 
  Power consumptions (CR2032 3.0V coin cell battery power supply) 
 
Rating 
Typ 
Unit 
TX current (@0dBm) 
12 
mA 
RX current 
13 
mA 
 
Power mode 
Average current   
Unit 
Idle mode
*1
 
200 
uA 
Sleep mode
*2
 
20 
uA 
Deep-Sleep mode
*3
 
uA 
Power-Down mode
*4
 
0.3 
uA 
 
*1 Idle mode is where the module enters per default after power up. In this mode, Xtal oscillator ON, RC oscillator ON, RF state OFF; 
*2 Sleep mode is a low power mode of the module. n this mode, Xtal oscillator OFF, RC oscillator ON, RF state OFF; 
*3 Deep-Sleep mode is the low power mode with the lowest power consumption. In this mode, Xtal oscillator OFF, RC oscillator OFF, RF 
state OFF; 
*4 Power-Down mode is the mode that the power of the module is shut down by external MCU. This mode is only used in the condition 
that the power of the module is controllable by MOSFET or LDO etc. through the external MCU. 
 
  Timming characteristics 
 
Rating 
Typ 
Unit 
Power up->Idle mode (Start 
up time) 
15.5 
ms 
Sleep->Idle mode 
2.6 
ms 
Deep-Sleep->Idle mode 
2.7 
ms 
 
 
Overall Dimensions 
 
The overall dimensions of BDE-BLEM101A is shown as Fig.2.