6.2.  GENERAL   
 
 
1.  Access Port: Select “0001 ~ 9999”   
Enter the port number the client uses to communicate with the NVR over the internet. 
The default port is 7000. It is recommended to use a port above 1000.   
2.  Bandwidth:  Select  the  network  bandwidth  to  limit  the  amount  of  network  resources 
allocated to client connection. The default is unlimited: “ 
4 KBPS ~ 8 MBPS”
 
3.  Access Block    1) Ping Block: No response to ping. By default OFF. 
2) Scan Block: No response to Auto Scan from EMS. By default OFF. 
4.  Access Host and Host List: Allows you to access or deny specific IP address.   
To allow or deny remote access requires you to enter a range of IP addresses as an 
IP address and mask.    Host List will be activated when you select deny or allowed.   
 
5.  Auto  Port  FWD: 
Select  the  ADD  button  to  automatically  open  ports  for  Router 
communication with UPNP compliance.
 
 
6.  2 Way Audio: Support 2 way Audio between NVR and Remote Software